首页 | 本学科首页   官方微博 | 高级检索  
检索        

Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study
引用本文:王娟,周义成,胡宁,王仁法.Application of Multislice Spiral CT for Guidance of Insertion of Thoracic Spine Pedicle Screws: An in vitro study[J].华中科技大学学报(医学英德文版),2006,26(4):485-488.
作者姓名:王娟  周义成  胡宁  王仁法
作者单位:Department of Radiology Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China,Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China,Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China,Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China
摘    要:The pedicle screws and the technology of insertion be- came one of the most important methods for the treat- ment of the spine diseases. In clinical practice, pedicle screws might be misplaced and cause severe complica- tions. The purpose of this study was to obtain the data by three-dimensional reconstruction of multi-slice spiral CT (MSCT) to guide the placement of pedicle screws. 1 MATERIALS AND METHODS 1.1 Materials Two embalmed human cadaveric thoracic pedicle spines (T1-T10) w…

关 键 词:CT检查  胸脊柱  肿瘤茎部  治疗
收稿时间:2005-03-01

Application of multislice spiral CT for guidance of insertion of thoracic spine pedicle screws: An in vitro study
Juan Wang,Yicheng Zhou,Ning Hu,Renfa Wang.Application of multislice spiral CT for guidance of insertion of thoracic spine pedicle screws: An in vitro study[J].Journal of Zuazhong University of Science and Technology: Medical Edition,2006,26(4):485-488.
Authors:Juan Wang  Yicheng Zhou  Ning Hu  Renfa Wang
Institution:Department ofRadiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030,China
Abstract:To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws. After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer. Analy- sis of variance demonstrated that the difference between the CT scans and real objects had no statis- tical significance (P>0.05). Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P>0.05). The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement of pedicle screws.
Keywords:spondylarthropathies  tomography  X-ray computed imaging  three-dimension
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号