首页 | 本学科首页   官方微博 | 高级检索  
检索        

DoseRight技术条件下不同定位像对儿童腹部CT辐射剂量及图像质量的影响
引用本文:仲晶晶,边传振,戴石,卞宠平.DoseRight技术条件下不同定位像对儿童腹部CT辐射剂量及图像质量的影响[J].蚌埠医学院学报,2022,47(1):94-98.
作者姓名:仲晶晶  边传振  戴石  卞宠平
作者单位:南京医科大学附属儿童医院 放射科, 江苏 南京 210008
基金项目:江苏省妇幼协会科研项目FYX201918
摘    要:目的:比较采用正位定位像、侧位定位像和双定位像在DoseRight技术条件下进行儿童腹部CT检查时对图像质量和辐射剂量的影响.方法:前瞻性收集行腹部CT检查的1~17岁患儿388例,依据患儿年龄分为1~6岁组(A组)、7~12岁组(B组)和13~17岁组(C组),每组患儿采用随机数字法分别分配到正位定位像组、侧位定位像...

关 键 词:电子计算机体层扫描  定位像  DoseRight技术  辐射剂量  儿童
收稿时间:2020-03-25

Effect of different positioning images on the radiation dose and image quality of abdominal CT in children under DoseRight technology
ZHONG Jing-jing,BIAN Chuan-zhen,DAI Shi,BIAN Chong-ping.Effect of different positioning images on the radiation dose and image quality of abdominal CT in children under DoseRight technology[J].Journal of Bengbu Medical College,2022,47(1):94-98.
Authors:ZHONG Jing-jing  BIAN Chuan-zhen  DAI Shi  BIAN Chong-ping
Institution:Department of Radiology, The Children's Hospital Affiliated to Nanjing Medical University, Nanjing Jiangsu 210008, China
Abstract:ObjectiveTo compare the effects of the anteroposteric, lateral and dual positioning images on the image quality and radiation dose in children abdominal CT examination under DoseRight technology.MethodsThe data of abdominal CT examination in 388 children aged 1-17 years were prospectively analyzed.According to the age, the children were divided into the 1-6 years old group(group A), 7-12 years old group(group B) and 13-17 years old group(group C).The children in each group were assigned to the anteroposteric, lateral and double positioning groups by random number method.The Philips 128 iCT was used for the data collection, the scan range and volume CT dose index(CTDIVOL) were recorded, the size-specific dose estimate(SSDE) were calculated, and the image qualities were subjectively and objectively evaluated in three groups.ResultsThe differences of CTDIVOL and SSDE among three groups were statistically significant(P < 0.01), which in anteroposterior positioning group were higher than those in lateral positioning group, and which in lateral positioning group were higher than those in dual positioning group(P < 0.05).The subjective scores of the image quality in three groups were more than or equal to 3 points, which met the diagnostic requirements.There was no statistical significance in the subjective score of image quality among three groups(P>0.05).ConclusionsThe application of dual positioning images in children abdominal CT examination can accurately control the scan range, reduce the radiation dose and ensure the image quality.
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《蚌埠医学院学报》浏览原始摘要信息
点击此处可从《蚌埠医学院学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号