首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of image quality and patient discomfort in prostate MRI: pelvic phased array coil vs. endorectal coil
Authors:Borna K. Barth  Alexander Cornelius  Daniel Nanz  Daniel Eberli  Olivio F. Donati
Affiliation:1.Institute of Diagnostic and Interventional Radiology,University Hospital Zurich and University of Zurich,Zurich,Switzerland;2.Department of Radiology, Cantonal Hospital Aarau,Aarau,Switzerland;3.Department of Urology,University Hospital Zürich and University of Zurich,Zurich,Switzerland
Abstract:

Purpose

To compare image quality (IQ) and patient discomfort during prostate MRI using a pelvic phased array (PPA) coil and an endorectal (ER) coil.

Materials and methods

Ninety-eight patients (median age, 65.7; range 42.1–78.1) underwent prostate MRI on a 3T scanner including T2w and DWI acquired with PPA and an ER coil within the same exam. Acquisition time was kept similar for both acquisitions. Two radiologists evaluated aspects of IQ on a 5-point Likert scale and classified image artifacts. All patients completed a questionnaire on discomfort/pain regarding the ER coil using a visual analogue scale from 1 to 10.

Results

There was no significant difference in overall IQ for T2w images for both readers (reader 1, 3.27 ± 0.91 and 3.07 ± 0.84, p = 0.057; reader 2, 3.70 ± 0.75 and 3.77 ± 0.81, p = 0.555) for PPA and ER coils, respectively. Overall IQ for DWI acquired with PPA and ER coils was rated similar by reader 1 (3.03 ± 1.10 and 3.08 ± 0.80, respectively, (p = 0.67)), while reader 2 preferred ER coil images (3.27 ± 0.81 and 3.66 ± 0.85 (p < 0.05)). Susceptibility artifacts were more frequent in ER than in PPA coil images (109 vs. 75). Discomfort and pain experienced during insertion of the ER coil was low altogether (VAS score, 3.5 ± 2.1 for “discomfort” and 2.4 ± 2.4 for “pain”).

Conclusion

T2-weighted images may be acquired with comparable IQ using a PPA coil as compared to an ER coil, while DWI images showed better IQ using the ER coil for one of two readers. The insertion of the ER coil caused low to moderate discomfort and pain in patients.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号