保乳术后固定野动态调强与容积调强放疗的剂量学比较
引用本文:铁剑,孙艳,弓健,韩树奎,蒋璠,吴昊. 保乳术后固定野动态调强与容积调强放疗的剂量学比较[J]. 中华放射医学与防护杂志, 2011, 31(3): 317-321. DOI: 10.3760/cma.j.issn.0254-5098.2011.03.017
作者姓名:铁剑  孙艳  弓健  韩树奎  蒋璠  吴昊
作者单位:北京肿瘤医院暨北京市肿瘤防治研究所放疗科,恶性肿瘤发病机制及转化研究教育部重点实验室,北京大学临床肿瘤学院,100142
摘    要:目的 比较早期乳腺癌保乳术后固定野动态调强与容积调强放疗治疗靶区和危及器官的剂量学差异.方法 20例左侧乳腺癌患者(均女性,24~75岁)保乳术后接受放疗,在同一患者CT影像上分别进行2野共面动态调强和容积调强(RapidArc)两种治疗计划设计.在剂量-体积直方图中读取两种计划的靶区剂量分布参数,心脏、双侧肺及对侧乳腺受照剂量和体积,对各参数的均数进行比较;并比较两者平均机器跳数和平均治疗时间的差异.结果 RapidArc较IMRT计划CTV V95%增加了0.65%(t=5.16,P=0.001),V105%下降了10.96%(t=-2.05,P=0.055),V110%下降了1.48%(t=-1.33,P=0.197).RapidArc计划的适形指数(CI)和均匀性指数(HI)均优于IMRT治疗计划,分别为0.88±0.02 vs 0.74±0.03(t=18.54,P<0.001),1.11±0.01 Vs 1.12±0.02(t=-2.44,P=0.025).两种计划中左肺V20和Dmax比较差异无统计学意义,但在RapidArc计划中V10、V5、Dmix、Dmean明显增高,V5增高了接近30%.心脏V30和Dmax在两计划中无明显差异,而RapidArc计划的V10增加了18%,V5增加50%.RapidArc计划的右乳V5和右肺V5较IMRT分别增加了9.33%(t=9.31,P<0.001)和3.04%(t=5.64,P<0.001).RapidArc和IMRT平均机器跳数分别是608和437 MU(t=10.86,P<0.001),平均治疗时间111.3和103.6 s(t=3.57,P=0.002).结论 早期乳腺癌保乳术后全乳腺RapidAre放疗与2野动态调强放疗相比,能明显改善靶区剂量分布均匀性.对于危及器官,高剂量区两种治疗计划之间无明显差异,低剂量区RapidArc的照射范围明显增加.与2野动态调强相比,RapidArc放疗机器跳数增加,治疗时间延长.
Abstract:
Objective To compare the dosimetric difference between volumetric are modulation with RapidArc and fixed field dynamic IMRT for breast cancer radiotherapy after breast-conserving surgery.Methods Twenty patients with early left-sided breast cancer received radiotherapy after breast-conserving surgery.After target definition,treatment planning was performed by RapidAre and two fixed fields dynamic IMRT respectively on the same CT scan.The target dose distribution,homogeneity of the breast,and the irradiation dose and volume for the lungs,heart,and eontralateral breast were read in the dosevolume histogram (DVH) and compared between RapidAre and IMRT.The treatment delivery time and monitor units were also compared.Results In comparison with the IMRT planning,the homogeneity of clinical target volume (CTV) ,the volume proportion of 95% prescribed dose (V95%) was significantly higher by 0.65% in RapidAre (t =5.16,P = 0.001) ,and the V105% and V110% were lower by 10.96% and 1.48 % respectively,however,without statistical significance (t =-2.05 ,P =0.055 and t =-1.33 ,P =0.197).The conformal index of planning target volume (PTV) by the Rap~dAre planning was (0.88±0.02),significantly higher than that by the IMRT planning [(0.74±0.03),t = 18.54,P < 0.001].The homogeneity index (HI) of PTV by the RapidArc planning was 1.11±0.01,significantly lower than that by the IMRT planning (1.12±0.02,t =-2.44,P =0.02).There were no significant differences in the maximum dose (Dmax) and V20 for the ipsilateral lung between the RapidArc and IMRT planning,but the values of V10,V5 ,Dmin and Dmean by RapidArc planning were all significantly higher than those by the IMRT planning (all P < 0.01).The values of max dose and V30 for the heart were similar by both techniques,but the values of V10 and V5 by the RapidArc planning were significantly higher (by 18% and 50% ,respectively).The V5 of the contralateral breast and lung by the RapidArc planning were increased by 9.33% and 3.04% respectively compared to the IMRT planning.The mean MU of the RapidArc was 608 MU,significantly higher than that by the IMRT planning (437 MU,t = 10.86,P < 0.001).The treatment time by the RapidArc planning was 111.3 s,significantly longer than that by IMRT planning (103.6 s,t = 3.57,P = 0.002).Conclusions The RapidArc planning improves the dose distribution of CTV and homogeneity of PTV for breast cancer radiotherapy after breast-conserving surgery.However,it significantly enlarges the volume of normal tissues irradiated in low dose areas,prolongs the treatment delivery time,and increases the MU value in comparison with IMRT.

关 键 词:乳腺癌  保乳手术  调强放疗  容积调强放疗  剂量学比较
收稿时间:2010-09-15

Dosimetric study comparing volumetric arc modulation with RapidArc and fixed field dynamic intensity-modulated radiation therapy for breast cancer radiotherapy after breast-conserving surgery
TIE Jian,SUN Yan,GONG Jian,HAN Shu-kui,JIANG Fan and WU Hao. Dosimetric study comparing volumetric arc modulation with RapidArc and fixed field dynamic intensity-modulated radiation therapy for breast cancer radiotherapy after breast-conserving surgery[J]. Chinese Journal of Radiological Medicine and Protection, 2011, 31(3): 317-321. DOI: 10.3760/cma.j.issn.0254-5098.2011.03.017
Authors:TIE Jian  SUN Yan  GONG Jian  HAN Shu-kui  JIANG Fan  WU Hao
Affiliation:Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University School of Oncology, Beijing Cancer Hospital & Institute, Beijing 100142, China;Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University School of Oncology, Beijing Cancer Hospital & Institute, Beijing 100142, China;Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University School of Oncology, Beijing Cancer Hospital & Institute, Beijing 100142, China;Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University School of Oncology, Beijing Cancer Hospital & Institute, Beijing 100142, China;Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University School of Oncology, Beijing Cancer Hospital & Institute, Beijing 100142, China;Key Laboratory of Carcinogenesis and Translational Research(Ministry of Education), Department of Radiation Oncology, Peking University School of Oncology, Beijing Cancer Hospital & Institute, Beijing 100142, China
Abstract:Objective To compare the dosimetric difference between volumetric are modulation with RapidArc and fixed field dynamic IMRT for breast cancer radiotherapy after breast-conserving surgery.Methods Twenty patients with early left-sided breast cancer received radiotherapy after breast-conserving surgery.After target definition,treatment planning was performed by RapidAre and two fixed fields dynamic IMRT respectively on the same CT scan.The target dose distribution,homogeneity of the breast,and the irradiation dose and volume for the lungs,heart,and eontralateral breast were read in the dosevolume histogram (DVH) and compared between RapidAre and IMRT.The treatment delivery time and monitor units were also compared.Results In comparison with the IMRT planning,the homogeneity of clinical target volume (CTV) ,the volume proportion of 95% prescribed dose (V95%) was significantly higher by 0.65% in RapidAre (t =5.16,P = 0.001) ,and the V105% and V110% were lower by 10.96% and 1.48 % respectively,however,without statistical significance (t =-2.05 ,P =0.055 and t =-1.33 ,P =0.197).The conformal index of planning target volume (PTV) by the Rap~dAre planning was (0.88±0.02),significantly higher than that by the IMRT planning [(0.74±0.03),t = 18.54,P < 0.001].The homogeneity index (HI) of PTV by the RapidArc planning was 1.11±0.01,significantly lower than that by the IMRT planning (1.12±0.02,t =-2.44,P =0.02).There were no significant differences in the maximum dose (Dmax) and V20 for the ipsilateral lung between the RapidArc and IMRT planning,but the values of V10,V5 ,Dmin and Dmean by RapidArc planning were all significantly higher than those by the IMRT planning (all P < 0.01).The values of max dose and V30 for the heart were similar by both techniques,but the values of V10 and V5 by the RapidArc planning were significantly higher (by 18% and 50% ,respectively).The V5 of the contralateral breast and lung by the RapidArc planning were increased by 9.33% and 3.04% respectively compared to the IMRT planning.The mean MU of the RapidArc was 608 MU,significantly higher than that by the IMRT planning (437 MU,t = 10.86,P < 0.001).The treatment time by the RapidArc planning was 111.3 s,significantly longer than that by IMRT planning (103.6 s,t = 3.57,P = 0.002).Conclusions The RapidArc planning improves the dose distribution of CTV and homogeneity of PTV for breast cancer radiotherapy after breast-conserving surgery.However,it significantly enlarges the volume of normal tissues irradiated in low dose areas,prolongs the treatment delivery time,and increases the MU value in comparison with IMRT.
Keywords:Breast cancer  Breast-conserving surgery  Intensity modulated radiation therapy  Volumetric modulated arc therapy  Dosimetry