首页 | 本学科首页   官方微博 | 高级检索  
     


Catecholamine Vasopressor Exposure Is Associated With Early Poor Allograft Function and Adverse Events in Living Donor Kidney Transplant Recipients
Affiliation:1. Department of Surgery, University of Illinois at Chicago College of Medicine, Chicago, Illinois;2. Department of Pharmacy Practice, University of Illinois at Chicago College of Pharmacy, Chicago, Illinois;2. Centre de recherche de l''Hôpital du Sacré-Cœur de Montréal, University of Montreal, Quebec, Canada;3. Institute for Health Policy, Management, and Evaluation, University of Toronto, Toronto, Canada;4. Extracorporeal Life Support Program, Toronto General Hospital, University of Toronto, Toronto, Canada
Abstract:BackgroundHypoperfusion leads to allograft injury during kidney transplantation. Catecholamine vasopressors are used to maintain blood pressure in the perioperative period but have demonstrated negative outcomes in the deceased-donor kidney transplant population. Little is known regarding living donor kidney transplants (LDKTs) and vasopressor use. The aim of this study is to describe the incidence of vasopressor use in LDKT and characterize its effects on allograft function and patient outcomes.MethodsThis retrospective, observational cohort study included adult patients who underwent an isolated LDKT between August 1, 2017, and September 1, 2018. Patients were divided into those who received perioperative vasopressors and those who did not. The primary objective was to compare allograft function between LDKT recipients that received vasopressors and those who did not. Secondary outcomes included safety endpoints and the identification of clinical variables associated with vasopressor use.ResultsA total of 67 patients received an LDKT during the study period. Of those, 25 (37%) received perioperative vasopressors, and 42 (62%) did not. Poor graft function, as defined by the development of slow or delayed graft function, occurred more frequently in patients receiving perioperative vasopressors compared with those who did not (6 [24%] vs 1 [2.4%], P = .016). In multivariable regression modeling, only perioperative vasopressors were statistically significantly associated with poor graft function. In addition, patients exposed to vasopressors experienced more postoperative arrhythmias (8 [32%] vs 1 [4.8%], P = .0025).ConclusionUsing perioperative vasopressors was independently associated with worsened early renal allograft function, including delayed graft function and adverse events in the LDKT population.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号