Abstract: | Abstract: This paper dicusses the use of esophageal dilatation with a Rigiflex TTS balloon. This method was used 45 times on 11 patients affected by anastomotic or a severe grade peptic esophageal stenosis. Fluoroscopic guidance was used in 36 procedures (80%) without effecting the mean duration of the treatment (12 minutes). The results were considered satisfactory when these goals had been achieved: a) dilatation of the stenosis over 15 mm; b) a dysphagia free-time of more than 6 months. A satisfactory result was achieved in 10 patients (90.9%), without deaths and major complications. 5 patients received 1 dilatation and the other 5 needed, 3-3-4-7–11 procedures respectively to obtain a satisfactory result. On these basis we consider that its great efficacy, security and tolerability depend on the following characteristics of the Rigiflex TTS balloon: 1) “radial” dilatation; 2) the possibility of introducing the balloon through the operative channel of the fiberscope; 3) direct visualization of the stenosis during dilatation. The following disadvantages with this method are: the absence of a tactile sensation of dilatation and the elevated cost of the instrument. We conclude that the Rigiflex TTS balloon is an important alternative to guide-wire techniques, especially for the treatment of severe esophageal strictures. |