摘    要:目的 :建立双氯芬酸钠栓溶出度测定方法。方法 :比较转篮法和桨法 ,用一阶导数分光光度法检测 ,提取参数 (T50、Td、m ) ,并对参数进行相关性检验。结果 :两种方法溶出参数差异显著 ,桨法优于转篮法。结论 :本试验方法可用于产品质量控制 ,质控标准为45min溶出量不少于标示量的80 %。

关 键 词:双氯芬酸钠栓  溶出度测定  一阶导数分光光度法
文章编号:1001-0408(2001)07-0427-02
修稿时间:2000-11-28

Study on Dissolution Test Methods for Diclofenac Sodium Suppository
XU Chuhong,LU Yongning,WANG Hu. Study on Dissolution Test Methods for Diclofenac Sodium Suppository[J]. China Pharmacy, 2001, 12(7): 427-428
Authors:XU Chuhong  LU Yongning  WANG Hu
Abstract:OBJECTIVE:To establish a good method for determining the dissolution rates of diclofenac sodium suppository METHODS:The dissolution method Ⅰ and Ⅱ of ChP(2000) were compared,the first derivative spectrophotometry was used and the parameters(T50,Td,m) obtained from these samples were brought for correlation analysis RESULTS:The dissolution rate of diclofenac sodium suppository from the dissolution method Ⅰ and Ⅱ were remarkably different,and the dissolution method Ⅱ was better than Ⅰ CONCLUSION:The method established by this study is suitable for the quality control of diclofenac sodium suppository,and the percentage of dissolution of diclofenac sodium suppository in 45min more than 80% is the standard of quality control