摘    要:目的探讨腋温的最佳测量时间。方法抽取院系学生296名,在同一时间将2支体温计汞端分别置于左、右腋窝深处,固定一侧测量10min(对照组),另一侧分别夹取3、4、5、6、7、8、9min(实验组)。结果实验组7个时间段与其对应的对照组体温测量结果均有显著性差异(P<0.001)。结论腋温的最佳测量时间为10min。

关 键 词:腋温  测量  时间

Research and practice of axillary temperature measurement at interval
LI Shu-ying,LIN Min,HUANG Cai-hui.Research and practice of axillary temperature measurement at interval[J].Journal of Henan University,2012(1):48-49.
Authors:LI Shu-ying  LIN Min  HUANG Cai-hui
Institution:(College of Nursing,Zhengzhou University,Zhengzhou,Henan 450052,China)
Abstract:Objective To explore the best measure time of armpit temperature.Methods 296 students were selected from the department,two mercury thermometer were set on the right and left armpit depths at the same time,the measuring time of fixed side was 10 minutes(contrlo group),another side were clipped for 3 minutes,4 minutes,5 minutes,6 minutes,7 minutes,8 minutes,9 minutes(experimental group) respectively.Results The seven time and its corresponding control of temperature measurement,the result showed significant difference(P< 0.001).Conclusion The best time of axillary temperature measurement is 10 min.