Affiliation: | 1. St. Michael’s Hospital, University of Toronto, Toronto, Ontario, Canada;2. Zentrum für Kardiologie, Universitätsmedizin Mainz, Johannes Gutenberg Universität, Mainz, Germany;3. St. Paul’s Hospital, Centre for Heart Valve Innovation, University of British Columbia, Vancouver, British Columbia, Canada;4. NewYork-Presbyterian Hospital, Columbia University Medical Center, New York, New York, USA;5. Baylor Scott & White Heart and Vascular Hospital, Dallas, Texas, USA;6. Medizinische Klinik und Poliklinik I, Klinikum der Universität München, Munich, Germany, USA;7. DZHK (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany |
| |
Abstract: | ObjectivesThe purpose of this observational first-in-human experience was to investigate the feasibility and safety of the EVOQUE tricuspid valve replacement system and its impact on short-term clinical outcomes.BackgroundTranscatheter tricuspid intervention is a promising option for selected patients with severe tricuspid regurgitation (TR). Although transcatheter leaflet repair is an option for some, transcatheter tricuspid valve replacement (TTVR) may be applicable to a broader population.MethodsTwenty-five patients with severe TR underwent EVOQUE TTVR in a compassionate-use experience. The primary outcome was technical success, with NYHA (NYHA) functional class, TR grade, and major adverse cardiac and cerebrovascular events assessed at 30-day follow-up.ResultsAll patients (mean age 76 ± 3 years, 88% women) were at high surgical risk (mean Society of Thoracic Surgeons risk score 9.1 ± 2.3%), with 96% in NYHA functional class III or IV. TR etiology was predominantly functional, with mean tricuspid annular diameter of 44.8 ± 7.8 mm and mean tricuspid annular plane systolic excursion of 16 ± 2 mm. Technical success was 92%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 0%, 76% of patients were in NYHA functional class I or II, and TR grade was ≤2+ in 96%. Major bleeding occurred in 3 patients (12%), 2 patients (8%) required pacemaker implantation, and 1 patient (4%) required dialysis.ConclusionsThis first-in-human experience evaluating EVOQUE TTVR demonstrated high technical success, acceptable safety, and significant clinical improvement. Larger prospective studies are needed to confirm durability and safety and the impact on long-term clinical outcomes. |
| |
Keywords: | EVOQUE transcatheter tricuspid valve replacement tricuspid regurgitation CT" },{" #name" :" keyword" ," $" :{" id" :" kwrd0030" }," $$" :[{" #name" :" text" ," _" :" computed tomographic FAC" },{" #name" :" keyword" ," $" :{" id" :" kwrd0040" }," $$" :[{" #name" :" text" ," _" :" fractional area change HF" },{" #name" :" keyword" ," $" :{" id" :" kwrd0050" }," $$" :[{" #name" :" text" ," _" :" heart failure IVC" },{" #name" :" keyword" ," $" :{" id" :" kwrd0060" }," $$" :[{" #name" :" text" ," _" :" inferior vena cava NYHA" },{" #name" :" keyword" ," $" :{" id" :" kwrd0070" }," $$" :[{" #name" :" text" ," _" :" New York Heart Association RA" },{" #name" :" keyword" ," $" :{" id" :" kwrd0080" }," $$" :[{" #name" :" text" ," _" :" right atrial RV" },{" #name" :" keyword" ," $" :{" id" :" kwrd0090" }," $$" :[{" #name" :" text" ," _" :" right ventricular TAPSE" },{" #name" :" keyword" ," $" :{" id" :" kwrd0100" }," $$" :[{" #name" :" text" ," _" :" tricuspid annular plane systolic excursion TR" },{" #name" :" keyword" ," $" :{" id" :" kwrd0110" }," $$" :[{" #name" :" text" ," _" :" tricuspid regurgitation TTVr" },{" #name" :" keyword" ," $" :{" id" :" kwrd0120" }," $$" :[{" #name" :" text" ," _" :" transcatheter tricuspid valve repair TTVR" },{" #name" :" keyword" ," $" :{" id" :" kwrd0130" }," $$" :[{" #name" :" text" ," _" :" transcatheter tricuspid valve replacement |
本文献已被 ScienceDirect 等数据库收录! |
|