首页 | 本学科首页   官方微博 | 高级检索  
     


Short-Term Clinical Outcomes of Transcatheter Tricuspid Valve Repair With the Third-Generation MitraClip XTR System
Authors:Tobias Friedrich Ruf  Rebecca T. Hahn  Felix Kreidel  Andres Beiras-Fernandez  Michaela Hell  Patrick Gerdes  Jaqueline Grace da Roche e Silva  Markus Vosseler  Martin Geyer  Alexander Tamm  Thomas Münzel  Ralph Stephan von Bardeleben
Affiliation:1. Department of Cardiology, Heart Valve Center, University Medical Center Mainz, Mainz, Germany;2. Cardiology Department, NewYork-Presbyterian/Columbia University Medical Center, New York, New York, USA;3. Department of Heart and Vascular Surgery, Heart Valve Center University Medical Center Mainz, Mainz, Germany
Abstract:ObjectivesThe aim of this study was to assess 30-day outcomes of transcatheter edge-to-edge repair with the MitraClip XTR for significant tricuspid regurgitation (TR), relative to baseline coaptation gap sizes (CGS).BackgroundTranscatheter edge-to-edge repair using the MitraClip NT for patients with significant TR is safe and efficacious; the utility of the MitraClip XTR is unknown.MethodsPatients with significant, symptomatic TR treated at a single site between April 2018 and December 2019, with consent and with complete data, were included (n = 50). Baseline and 30-day echocardiograms were assessed by an echocardiography core laboratory. Patients were divided into 3 subgroups on the basis of site-assessed CGS: subgroup I (< 7 mm), subgroup II (7 to 10 mm), and subgroup III (>10 mm).ResultsTechnical success of the MitraClip XTR implantation was 100% (88% in the septal-anterior position) using a median of 2 clips (interquartile range: 1 to 2). At 30 days, single-leaflet detachment was noted in 3 patients (6%), with no instances of device embolization. TR was reduced by 1 grade in subgroup I and by 2 grades in subgroups II and III. New York Heart Association functional class was reduced by 1 class in all 3 subgroups. The 6-min walk distance increased in subgroup I (+115 m; p = 0.014) and subgroup II (+31.5 m; p = 0.028) but not subgroup III (+50 m; p = 0.999). A CGS of ≤8.4 mm was predictive of a reduction to moderate or less TR.ConclusionsMitraClip XTR implantation is a safe, effective treatment for a wider range of CGS in patients with symptomatic, significant TR than prior device iterations. All patients showed improvement in New York Heart Association functional class, and those with CGS <10 mm also experienced improved functional capacity.
Keywords:transcatheter  tricuspid regurgitation  tricuspid valve  6MWD"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0030"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  6-min walk distance  BNP"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0040"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  brain natriuretic peptide  CGS"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0050"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  coaptation gap size(s)  CI"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0060"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  confidence interval  NYHA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0070"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  New York Heart Association  TEER"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0080"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transcatheter edge-to-edge repair  TR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0090"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  tricuspid regurgitation  VCW"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0100"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  vena contracta width
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号