首页 | 本学科首页   官方微博 | 高级检索  
     


Scavenging anesthetic gas from a membrane oxygenator during cardiopulmonary bypass
Authors:Homishak M  Widmer S  Stauffer R
Affiliation:Perfusion Department, St. Luke's Hospital, Bethlehem, PA 18015, USA.
Abstract:
Concerns remain about the acute and chronic effects on personnel of waste anesthetic gases in the operating room environment. This study demonstrates a simple and effective means of scavenging waste anesthetic gases when halogenated anesthetics are administered through the pump oxygenator during cardiopulmonary bypass. This technique safeguards workers' health by reducing ambient anesthetic levels below the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limits.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏