首页 | 本学科首页   官方微博 | 高级检索  
     

柱切换高效液相色谱法测定维生素D滴剂、维生素AD滴剂中维生素D的含量
引用本文:林思荣,王勇,林晨,王磊,许永彬,石贞香,林芳,陈鼎雄. 柱切换高效液相色谱法测定维生素D滴剂、维生素AD滴剂中维生素D的含量[J]. 药物分析杂志, 2021, 0(3): 491-500
作者姓名:林思荣  王勇  林晨  王磊  许永彬  石贞香  林芳  陈鼎雄
作者单位:福建省食品药品质量检验研究院;江苏省泰州市人民医院;厦门市食品药品质量检验研究院;国药控股星鲨制药(厦门)有限公司
基金项目:2018年度国家药品标准提高-维生素D含量测定法(二维色谱法)(2018Y006);福建省科学技术厅项目(2019Y0065)。
摘    要:
目的:建立用于快速测定维生素D滴剂、维生素AD滴剂中维生素D含量的柱切换二维液相色谱方法.方法:样品用正己烷溶解后直接注入液相色谱系统,在第一维色谱完成前维生素D3、维生素D3的初步净化;以9 mL大体积的收集流路收集合有前维生素D3、维生素D3的组分,在第二维色谱完成前维生素D3与维生素D3的分离和定量.本方法可以直...

关 键 词:柱切换  二维液相色谱  前维生素D3  维生素D3  维生素D滴剂  维生素AD滴剂  含量测定

Determination of vitamin D content in vitamin D drops and vitamin A D drops by column-switching high-performance liquid chromatography
LIN Si-rong,WANG Yong,LIN Chen,WANG Lei,XU Yong-bin,SHI Zhen-xiang,LIN Fang,CHEN Ding-xiong. Determination of vitamin D content in vitamin D drops and vitamin A D drops by column-switching high-performance liquid chromatography[J]. Chinese Journal of Pharmaceutical Analysis, 2021, 0(3): 491-500
Authors:LIN Si-rong  WANG Yong  LIN Chen  WANG Lei  XU Yong-bin  SHI Zhen-xiang  LIN Fang  CHEN Ding-xiong
Affiliation:(Fujian Institute for Food and Drug Quality Control,Fuzhou 350001,China;Jiangsu Taizhou Peopled Hospital,Taizhou 225300,China;Xiamen Institute for Food and Drug Quality Control,Xiamen 361012,China;Sinopharm Xingsha Pharm aceuticals(Xiamen)Co.,Ltd,Xiamen 361028,China)
Abstract:
Objective:To develop a rapid method for direct determination of vitamin D in vitamin D drops and vitamin A D drops using two-dimensional column switch liquid chromatography.Methods:The sample was dissolved in n-hexane and injected directly into the liquid chromatography system.Preliminary purification of pre-vitamin D3 and vitamin D3 were achieved in the first-dimensional liquid chromatography.The eluent containing pre-vitamin D3 and vitamin D3 from the first dimensional column was collected by a 9 mL collection pipe and then switched into the second dimensional column to complete quantification of pre-vitamin D3 and vitamin D3.Two kinds of liquid vitamin D supplements(vitamin D drops and vitamin A and D drops)were directly analyzed using this system without any complicated preparation procedure.Results:The linear range of pre-vitamin D3 and vitamin D3 in vitamin D drops and vitamin A and D drops was 0.1008-0.9072μg·mL-1 with the correlation coefficient of 0.9997.The RSDs of repeatability were 0.4% and 0.8%.The average recoveries were 100.5%(RSD=0.78%)and 100.7%(RSD=1.6%).The LOD was 1.6 ng·mL-1 and LOQ was 5.3 ng·mL-1.The contents of vitamin D3 in 7 batches of vitamin D drops ranged from 102.6%to 111.8%.The contents of vitamin D3 in 11 batches of vitamin A D drops ranged from 97.4%to 104.7%.Conclusion:The method is sensitive,accurate and easy to operate.It has a good application prospect for the determination of vitamin D3 in oily and fat soluble vitamin D preparations.
Keywords:column-switch  two-dimensional liquid chromatography  pre-vitamin D3  vitamin D3  vitamin D drops  vitamin A D drops  content determination
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号