首页 | 本学科首页   官方微博 | 高级检索  
     

酶放大免疫法与荧光偏振免疫法检测环孢素A血药浓度对比研究
引用本文:崔彦,周金玉,孙增先,马玉蓉. 酶放大免疫法与荧光偏振免疫法检测环孢素A血药浓度对比研究[J]. 中国药业, 2013, 0(19): 17-18
作者姓名:崔彦  周金玉  孙增先  马玉蓉
作者单位:[1]重庆市第五人民医院,重庆400062 [2]江苏省连云港市第一人民医院,江苏连云港222000
摘    要:
目的比较酶放大免疫法(EMIT)和荧光偏振免疫法(FPIA)检测人全血中环孢素A(CsA)质量浓度的相关性。方法收集肝移植患者服药后的稳态谷浓度血样78份,分别用TDx—FLx血药浓度测定仪和Viva—E血药浓度分析仪进行检测,测定值用线性回归分析和配对样本t检验进行对比研究。结果两种方法测定的CsA血药浓度无显著性差异,相关性良好(r=0.9809),线性回归方程为Y=1.0313X-11.268。结论应用Viva—E血药浓度分析仪检测患者全血中CsA的质量浓度准确、可靠。在无TDx—FLx血药浓度测定仪时,Viva—E血药浓度分析仪可作为测定CsA血药浓度的常规仪器。

关 键 词:酶放大免疫法  荧光偏振免疫法  环孢素A  治疗药物监测

Comparative Study of EMIT and FPIA in Detecting Concentration of Cyclosporine in Human Whole Blood
Cui Yan,Zhou Jinyu,Sun Zengxian,Ma Yurong. Comparative Study of EMIT and FPIA in Detecting Concentration of Cyclosporine in Human Whole Blood[J]. China Pharmaceuticals, 2013, 0(19): 17-18
Authors:Cui Yan  Zhou Jinyu  Sun Zengxian  Ma Yurong
Affiliation:1. Chongqing Municipal Fifth People's Hospital, Chongqing, China 400062; 2. Lianyungang Municipal First People's Hospital, Lianyungang, Jiangsu, China 222000)
Abstract:
Objective To compare the correlation of the enzyme muhiplied immunoassay technique(EMIT) and the fluorescence polariza- tion immunoassay(FPIA) in delecting the concentration of cyclosporine(CsA) in human whole blood. Methods Seventy-eight blood samples with steady- state trough concentration in the patients with liver transplantation after medication were collected for the determi- nation by the TDx- FLx and the Viva- E blood concentration analyzer respectively. The detection rusuhs were contrasted with paired- sample t test and the linear regression analysis. Results There was no statistical difference in the determination results of CsA between EMIT and FPIA, the correlation was well( r = 0. 980 9). The linear regression equation was Y= 1.031 3 X - 11. 268. Conclusion Using the Viva- E blood concentration analyzer for detecting the concentration of CsA in human whole blood is accurate and reliable. When the TDx- FLx blood concentration analyzer is absent, the Viva- E blood concentration analyzer can be used as the routine instrument for detecting the concentration of CsA in human whole blood.
Keywords:EMIT  FPIA  cyclosporine  therapeutic drug monitoring
本文献已被 维普 等数据库收录!