首页 | 本学科首页   官方微博 | 高级检索  
     

X射线行李包安检设备辐射泄漏量的MCNP模拟
引用本文:王凯,刘滨,胡文超,赵伟. X射线行李包安检设备辐射泄漏量的MCNP模拟[J]. 中国辐射卫生, 2011, 20(4): 390-393. DOI: 10.13491/j.cnki.issn.1004-714x.2011.04.039
作者姓名:王凯  刘滨  胡文超  赵伟
作者单位:华北电力大学, 北京 102206
摘    要:
目的 模拟计算地铁站所使用的X射线行李包安检设备辐射泄漏量的大小。方法 采用MCNP4C程序来模拟X射线安检设备在使用过程中X射线的泄漏量。结果 人体接受到的最大辐射剂量为8.26μSv/a,但如果能保持安检设备铅帘的完整性人体受到的辐射剂量仅为0.0727μSv/a。结论 当行李进出安检机并导致铅帘产生缝隙时,辐射泄漏量会显著增大;人体所受到的最大辐射量仍低于《电离辐射防护与辐射源安全基本标准》(GB18871-2002)中规定的10μSv/a的豁免标准。

关 键 词:安检设备  MCNP  辐射泄漏  X射线  
收稿时间:2011-04-04

The MCNP simulation of the X-ray leakage of X-ray security inspection Equipment
WANG Kai , LIU Bin , HU Wen-chao , ZHAO Wei. The MCNP simulation of the X-ray leakage of X-ray security inspection Equipment[J]. Chinese Journal of Radiological Health, 2011, 20(4): 390-393. DOI: 10.13491/j.cnki.issn.1004-714x.2011.04.039
Authors:WANG Kai    LIU Bin    HU Wen-chao    ZHAO Wei
Affiliation:North China Electric Power University, Beijing 102206 china
Abstract:
Objective To simulate the radiation leakage of the X-ray security inspection equipment used in the subways stations.Methods We use the MCNP4C code to simulate the X-ray leakage of the equipment during the working process.Result the biggest amount of radiation received by the body is 8.26μSv/a,however,if the Lead screens of the X-ray security equipment is intact,the amount of radiation received by the body is only 0.0727μSv/a.The final.Conclusions When the baggage get in /out the X-ray security inspection equipment,the gas in Lead screens was made,and then the amount of radiation received by human body increased;The amount of radiation received by the body is close to but still below 10μSv/a which is the exemption criteria set by the "safety of radiation sources of ionizing radiation protection and basic standards"(GB18871-2002).
Keywords:Security Inspection Equipment  MCNP  Radiation Leakage  X-ray  
本文献已被 CNKI 维普 万方数据 等数据库收录!