首页 | 本学科首页   官方微博 | 高级检索  
检索        


Chondroitin‐6‐sulfate incorporation and mechanical stimulation increase MSC‐collagen sponge construct stiffness
Authors:Kirsten RC Kinneberg  Victor S Nirmalanandhan  Natalia Juncosa‐Melvin  Heather M Powell  Steven T Boyce  Jason T Shearn  David L Butler
Institution:1. Tissue Engineering and Biomechanics Laboratories, Department of Biomedical Engineering, University of Cincinnati, 2901 Campus Drive, ML0048, Cincinnati, Ohio 45221‐0048;2. Office of Therapeutics, Discovery and Development, KU Medical Center, Kansas City, Kansas;3. Surgical Energetics, Inc., Cincinnati, Ohio;4. Department of Research, Engineered Skin Laboratory, Shriners Hospitals for Children, Cincinnati, Ohio;5. Department of Materials Science and Engineering, Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio;6. Department of Surgery, University of Cincinnati, Cincinnati, Ohio
Abstract:Using functional tissue engineering principles, our laboratory has produced tendon repair tissue which matches the normal patellar tendon force‐displacement curve up to 32% of failure. This repair tissue will need to withstand more strenuous activities, which can reach or even exceed 40% of failure force. To improve the linear stiffness of our tissue engineered constructs (TECs) and tissue engineered repairs, our lab is incorporating the glycosaminoglycan chondroitin‐6‐sulfate (C6S) into a type I collagen scaffold. In this study, we examined the effect of C6S incorporation and mechanical stimulation cycle number on linear stiffness and mRNA expression (collagen types I and III, decorin and fibronectin) for mesenchymal stem cell (MSC)‐collagen sponge TECs. The TECs were fabricated by inoculating MSCs at a density of 0.14 × 106 cells/construct onto pre‐cut scaffolds. Primarily type I collagen scaffold materials, with or without C6S, were cultured using mechanical stimulation with three different cycle numbers (0, 100, or 3,000 cycles/day). After 2 weeks in culture, TECs were evaluated for linear stiffness and mRNA expression. C6S incorporation and cycle number each played an important role in gene expression, but only the interaction of C6S incorporation and cycle number produced a benefit for TEC linear stiffness. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1092–1099, 2010
Keywords:tissue engineering  collagen‐GAG  mechanical stimulation  patellar tendon
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号