首页 | 本学科首页   官方微博 | 高级检索  
检索        

两种不同类型左心耳封堵器的动物实验研究
引用本文:汤学超,王飞宇,张志钢,秦永文.两种不同类型左心耳封堵器的动物实验研究[J].中国比较医学杂志,2021(1):106-112.
作者姓名:汤学超  王飞宇  张志钢  秦永文
作者单位:中国人民解放军联勤保障部队第960医院泰安院区心血管内科;空军杭州特勤疗养中心疗养二区;上海中医药大学附属普陀医院心血管内科;上海长海医院心血管内科
摘    要:目的 评价单盘圆柱型及双盘分体型两种不同左心耳封堵器进行动物左心耳封堵的可行性及安全性.方法 14只健康实验犬使用单盘圆柱型或双盘分体型左心耳封堵器经股静脉途径进行左心耳封堵,术中左房造影评价封堵后效果;对非预期死亡的实验犬立即进行大体标本检查分析死因,存活的实验犬分别于术后第45天、80天、110天、15月处死,对封...

关 键 词:心房纤颤  左心耳封堵术  左心耳封堵器  动物实验

Assessment of two different types of left atrial appendage occluder
TANG Xuechao,WANG Feiyu,ZHANG Zhigang,QIN Yongwen.Assessment of two different types of left atrial appendage occluder[J].Chinese Journal of Comparative Medicine,2021(1):106-112.
Authors:TANG Xuechao  WANG Feiyu  ZHANG Zhigang  QIN Yongwen
Institution:(Department of Cardiology,the 960^th Hospital of PLA,Tai'an 271000,China;Department of Rehabilitation and Physiotherapy,the Second Sub-Center of Air Force Healtheare Center for Special Services,Hangzhou 310007,China;Department of Cardiology,Putuo Hospital,Shanghai University of Traditional Chinese Medicine,Shanghai 200062;Department of Cardiology,Changhai Hospital,Shanghai 20043)
Abstract:Objective To evaluate the feasibility and safety of two different types of left atrial appendage occluder with a single disc cylinder or double disc device.Methods Fourteen healthy canines were subjected to left atrial appendage closure(LAAC)with the single disc cylinder or double disc device percutaneously.Closure was evaluated by left atrial angiography.The cause of death was analyzed by gross specimen examination of dogs that had died unexpectedly.The canines were sacrificed post-procedure at 45,80,110 days,and 15 months.Endothelialization of the device surface was evaluated by HE staining,immunofluorescence staining of CD31,and DAPI staining.Results Single disc cylinder devices were implanted in six canines,five of which died within 30 min to 8 h post-procedure,and one canine survived until 15 months.A large number of blood clots were formed on the device surface in four canines,and one-fifth of the device surface in the surviving canine was not covered by new tissue.Double disc occluders were implanted successfully in eight canines.The left atrial appendage of seven canines was sealed completely and a small residual shunt was observed in one canine immediately post-procedure.New tissue had covered the sealing disc completely on day 110.HE and immunofluorescence staining confirmed complete intima formation and neovascularization within 4 months.Conclusions The incidence of acute thrombosis and the mortality rate of LAAC with a single disc device were high.LAAC with double disc devices had less device-related complications and neointima formation was completed by 4 months post-procedure.
Keywords:atrial fibrillation  left atrial appendage closure  left atrial appendage occluder  animal experiment