LC determination of rofecoxib in bulk and pharmaceutical formulations |
| |
Authors: | Radhakrishna T Sreenivas Rao D Om Reddy G |
| |
Affiliation: | Department of Analytical Research, Dr Reddy's Research Foundation, Bollaram Road, Miyapur, Hyderabad 500 050, India. |
| |
Abstract: | ![]() An isocratic reversed phase-liquid chromatographic (RP-LC) method has been developed for the determination and purity evaluation of rofecoxib in bulk and pharmaceutical dosage forms using photodiode array detection set at 225 nm. The method is simple, rapid and selective. The method is capable of detecting all process intermediates and other related compounds, which may be present at trace levels in finished products. Hence the method is very useful for process monitoring during the production of rofecoxib. Chlorophenyl methyl sulphone has been used as internal standard for the quantitative determination of rofecoxib. The method is linear in the range of 125-500 microg. The precision for inter- and intra-day assay variation of rofecoxib is below 1.6% relative standard deviation (R.S.D.). The accuracy determined as relative mean error (R.M.E.) for the intra-day assay is within +/-2.0%. The drug was extracted from tablets (Vioxx) using acetonitrile. The percentage recoveries from dosage forms were ranged from 98.2 to 102.6. |
| |
Keywords: | |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|