摘    要:新型心电图仪是以MSP430F149单片机为核心,并用其自带的ADC12将心电信号采集下来的数据进行转换,存储在其FLASH里,实现存储数据和回放数据功能。通过采用低功耗的集成元件,以及精简集成的电路来实现一款低功耗抗干扰能力强的便携式的新型心电图仪。经测试,仪表运行稳定,数据可靠。

关 键 词:MSP430  心电图仪  便携式  设计

Anti-interference Design of Simple Electrocardiogram Machine Based on MSP430
WEI Fang-bo,JANG Yong. Anti-interference Design of Simple Electrocardiogram Machine Based on MSP430[J]. Medical Equipment, 2011, 24(10): 16-17
Authors:WEI Fang-bo  JANG Yong
Affiliation:WEI Fang-bo,JANG Yong (Department of Physics and Electronic Engineering,Yunyang Teachers'College,Danjiangkou 442700,China)
Abstract:New electrocardiogram takes MSP430F149 MCU as the core and with its ADC12,it can convert data of ECG signal acquisition and store them in FLASH,thus,ECG can be recorded and play-backing demonstrated.By adopting low-power integrated components and simplifying integrated circuit,the ECG has the following features,such as low power,high anti-interference ability and portability.Through the experiment,the stability and reliability of the ECG is confirmed.
Keywords:MSP430  Electrocardiogram  portability  Design  