3D打印和CAD/CAM氧化锆种植体骨结合性能的动物实验评价
引用本文:倪王成,胡琳驰,张维丹,周贝贝,黄温棉,朱秦天,余季兰,王仁飞. 3D打印和CAD/CAM氧化锆种植体骨结合性能的动物实验评价[J]. 口腔医学, 2021, 41(2): 144-148. DOI: 10.13591/j.cnki.kqyx.2021.02.008
作者姓名:倪王成  胡琳驰  张维丹  周贝贝  黄温棉  朱秦天  余季兰  王仁飞
作者单位:1. 浙江中医药大学2. 浙江中医药大学口腔医学院2016级研究生班3. 杭州口腔医院
基金项目:杭州市农业与社会发展科研计划
摘    要:
目的 比较3D打印和计算机辅助设计与制造(CAD/CAM)氧化锆种植体与纯钛种植体在动物体内的骨结合和成骨效果的差异,评价氧化锆种植体骨结合性能.方法 分别将3D打印氧化锆、CAD/CAM种植体和钛种植体各20枚随机植入6只Beagle犬的胫骨内,8周后观察氧化锆种植体的成功率和骨结合能力,并与钛种植体进行比较,观察指...

关 键 词:骨结合  氧化锆种植体  不脱钙种植体骨切片
收稿时间:2020-04-30

Animal experimental evaluation of bone-implant contact properties of 3D printed and CAD/CAM zirconia implants
NI Wangcheng,HU Linchi,ZHANG Weidan,ZHOU Beibei,HUANG Wenmian,ZHU Qintian,YU Jilan,WANG Renfei. Animal experimental evaluation of bone-implant contact properties of 3D printed and CAD/CAM zirconia implants[J]. Stomatology, 2021, 41(2): 144-148. DOI: 10.13591/j.cnki.kqyx.2021.02.008
Authors:NI Wangcheng  HU Linchi  ZHANG Weidan  ZHOU Beibei  HUANG Wenmian  ZHU Qintian  YU Jilan  WANG Renfei
Abstract:
Abstract: Objective To compare the 3D printed zirconia implants and computer aided design-computer assomated manufacture (CAD/CAM) zirconia implants and pure titanium implants in the differences in osseointegration in animals, and evaluated the osteointegration performance of zirconia implants for zirconia implantation in bones. Methods Six Beagle dogs were selected, and randomly planted 3D printed zirconia implants, CAD/CAM implants and titanium implants in tibias, 20 for each material. Success rate and osteointegration performance of zirconia implants were evaluated 8 weeks later. Osseointegration performance was compared with titanium implants. The observational indicators of this study were success rate of the bone implant, reverse torque test, bone-to-implant contact rate, and bone density around the implants. SPSS17.0 software package was used for statistical analysis of the data. Results The success rates of the three groups of bone implants were all 100%.The reverse torque values of CAD / CAM zirconia implant group were all greater than 35 N; the reverse torque values of zirconia implant group by 3D printed technology were all greater than 35 N; the reverse torque value of 2 implants in the titanium implant group was between 20 and 35 N, and the reverse torque value of 8 implants was greater than 35 N. Histological observation findings: The rates of bone osseointegration without marrow cavity of 3D printed zirconia implants, CAD/CAM zirconia implants and pure titanium implants exhibited (66.35±6.64%)、(61.32±10.41%)and(58.88±25.10%), respectively. The rates of bone osseointegration with marrow cavity of 3D printed zirconia implants, CAD/CAM zirconia implants and pure titanium implants displayed (49.57±5.04%)、(42.21±18.58%)and(38.45±23.27%), respectively. And the average rate of bone osseointegration of 3D printed zirconia implants, CAD/CAM zirconia implants and pure titanium implants revealed (58.94±6.31%)、(53.56±8.77%) and(48.31±20.76%), respectively. Moreover, the bone density around 3D printed zirconia implants, CAD/CAM zirconia implants and pure titanium implants demonstrated (60.59±7.31%), (58.50±6.36%) and (58.18±14.80%), respectively. There was no significant difference after data analysis (P> 0.05). Conclusions Zirconia implants have the similar osseointegration ability as pure titanium implants, and can form close direct bone contact. Therefore, zirconia implants may be an optional material for dental implants.
Keywords:Osseointegration   Zirconia implant   Non-decalcified implant bone section  
本文献已被 万方数据 等数据库收录!
点击此处可从《口腔医学》浏览原始摘要信息
点击此处可从《口腔医学》下载全文