Evaluation of aortic distensibility using cine MR imaging]
Authors:M Takahashi  K Murata  M Mori  N Kawaguchi  A Furukawa  M Okada  K Mitsunami  M Kinoshita  I Yamamoto  R Morita
Affiliation:Department of Radiology, Shiga University of Medical Science.
Abstract:Regional aortic distensibility was measured noninvasively using cine MR imaging to determine whether it correlates with aging or risk of coronary artery disease (CAD). Twenty-two patients with CAD confirmed by angiography and 33 without CAD underwent cine MR imaging. Thirty-two sequential images were obtained in one cardiac cycle. The cross sectional area of the descending thoracic aorta was measured on both diastolic (A) and systolic (A') images. Aortic distensibility (A.D.) was calculated from the following equation: A.D. = (A'-A)/A/delta P. (delta P represents pulse pressure). Results of a simple regression analysis showed that decreased regional aortic distensibility was significantly correlated with the age of the patients (r = -0.762, p less than 0.005). In addition, the parameter was lower in patients with CAD than those without CAD (p less than 0.05). In conclusion, regional aortic distensibility derived from cine MR imaging is a useful parameter to evaluate not only aging but also pathological atherosclerosis of the aorta. In addition, this parameter might have some potential to evaluate the prediction of CAD in patients with normal serum cholesterol.