首页 | 本学科首页   官方微博 | 高级检索  
检索        

前路器械内固定手术矫治脊椎侧凸
引用本文:周良安,陈之白.前路器械内固定手术矫治脊椎侧凸[J].中国矫形外科杂志,1996,3(2):106-107.
作者姓名:周良安  陈之白
作者单位:广东省人民医院骨科
摘    要:作者从1979年开始使用戴瓦氏手术,1983年开始使用斯伍基氏手术,至1994年共做57例(男性28例,女性29例),年龄为9~28岁。手术无死亡。术后并发症戴瓦氏手术:1例截瘫,2例椎体骨折伴螺丝钉拔出,2例螺丝钉折断,2例金属缆折断;斯伍基氏手术,1例杆折断,2例切口感染。

关 键 词:前路器械  脊椎侧凸  并发症预防

Prevention of Complication due to Anterior Route Instrumentation Operation for Correction of Scoliosis
Zhou Liangan,Chen Zhibai,ZhouKekuang..Prevention of Complication due to Anterior Route Instrumentation Operation for Correction of Scoliosis[J].The Orthopedic Journal of China,1996,3(2):106-107.
Authors:Zhou Liangan  Chen Zhibai  ZhouKekuang
Abstract:Dwyer procedure and Zielke procedure are most commonly used at present in anterior route instrumentation operation for correction of scoliosis,We began to carry on the former in 1979 and the latter in 1 983,and 57 cases were performed from 1979 to 1994(male 28 cases and female 29;age 9-28 years).The postoperative complications included(1)paraplegia in one case after Dwyer operation,(2)looseness of screws in 2,(3)break of screws in 2,(4)break of Dwyer cable in 2,(5)break of Zielke rod in 1,and(6)infection of wound in 2.We suggest and discuss the preventive management with the purpose of improving the operative result.
Keywords:Anterior route instrumentation  Scoliosis  Prevention of complication    