首页 | 本学科首页   官方微博 | 高级检索  
检索        


A Novel Multiparametric Score for the Detection and Grading of Prosthetic Mitral Valve Obstruction in Cases With Different Disc Motion Abnormalities
Institution:2. Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy;3. Centro Cardiologico Monzino IRCCS, Milan, Italy;4. Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy;5. Department of Mathematics, Politecnico di Milano, Milan, Italy;2. Ultrasound Department, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China;3. Department of Emergency Medicine, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA;4. Department of Imaging Diagnostics, Policlinico Umberto I, University Sapienza, Rome, Italy;5. Berner Institut für Hausarztmedizin (BIHAM), Universität Bern, Bern, Switzerland;11. Ultrasound Section, Division of Surgery, Department of Gastroenterology, Herlev Hospital Copenhagen Academy for Medical Education and Simulation Ultrasound Section, University of Copenhagen, Copenhagen, Denmark;12. Diagnostic Radiology Institute, Paula Stradina Clinical University Hospital, And Radiology Research Laboratory, Riga Stradins University University of Latvia, Riga, Latvia;8. Department of Obstetrics and Gynecology And Sono Education Academy, University Hospital Bonn, Bonn, Germany;9. College of Nursing and Health Sciences, Flinders University, Adelaide, SA, Australia;2. Department of Internal Medicine—Gastroenterology, Washington University School of Medicine, St. Louis, Missouri, USA;3. Department of Anatomic & Molecular Pathology, Washington University School of Medicine, St. Louis, Missouri, USA;4. Department of Mathematics and Statistics, Washington University, St. Louis, Missouri, USA;5. University of South Florida Health Heart Institute, Morsani School of Medicine, Tampa, Florida, USA;2. Department of Internal Medicine and Medical Disciplines, Sapienza University of Rome, Rome, Italy;3. Department of Medical Sciences, Casa Sollievo della Sofferenza Hospital, IRCCS, San Giovanni Rotondo (FG), Italy;4. Interventional Ultrasound Unit of Internal Medicine, Casa Sollievo della Sofferenza Hospital, IRCCS, San Giovanni Rotondo (FG), Italy;2. Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Berlin, Germany;2. Applied Physics Program, University of Michigan, Ann Arbor, Michigan, USA;3. Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA;2. Department of Anesthesiology, Vancouver General Hospital, Vancouver, Canada;3. Department of Ultrasound, BC Women''s Hospital, Vancouver, Canada
Abstract:Prosthetic mechanical valves are the elective choice in mitral valve (MV) replacement, because of their reliability and easiness of implantation. However, these prostheses can suffer from complications, the major one being prosthetic mitral valve thrombosis (PMVT). In these cases, transthoracic doppler echocardiogram (TDE) is the standard diagnostic workup for diagnosis of valve malfunction. The American Society of Echocardiography (ASE) indicates the possible TDE-derived indexes, which can help in identifying insurgence of MV replacement complications. Unfortunately, in some cases, it is not possible to detect PMVT based on these criteria. In these cases, we speak of Doppler silent thrombosis and only more accurate and invasive analyses, such as fluoroscopy, allow for a correct diagnosis. In this work, computational fluid dynamic models were implemented to simulate valve fluid dynamics in different clinical scenarios in order to improve the reliability of PMVT diagnosis based on TDE. In detail, seven mechanical valve configurations, associated to different potential thrombotic conditions (symmetric and asymmetric stenosis), were designed and tested using five pathologic transmitral velocity profile, extracted from real TDE images; to obtain the flow rate profiles, each TDE velocity profile was scaled to yield a mean flow rate (MFR) of 4, 5 and 6 L/min, respectively. As a result, 105 (7 × 5 × 3) synthetic cases, accounting for different velocity profiles, MFRs and valve configurations, were simulated. TDE-derived indexes were calculated according to the ASE guidelines that were extracted. Advanced statistical methods were applied to propose a new diagnostic algorithm for detecting PMVT. Our results showed that there isn't any significant difference between symmetric and asymmetric stenosis, probe location and flow rate waveform and confirmed that the single modality diagnostic is not able to predict thrombosis in a relevant number of cases, referable to mild and mild-severe stenosis cases. To overcome the problem, a novel multi-parametric discrete score based on the designed diagnostic algorithm was attained and tested; the percentage of stenosis (POS) was predicted with an accuracy rate of 90.5%. Even more interestingly, the error rate of 9.5% is related to four false positive cases corresponding to mild stenosis (POS = 15%) which were erroneously classified as mild-severe stenosis. No false negatives were obtained. Our results suggest that a reliable estimation must take into account the mean flow rate as well as the transmitral velocity profile in order to provide a correct diagnosis.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号