首页 | 本学科首页   官方微博 | 高级检索  
检索        


Clinical equivalence assessment of T2 synthesized pediatric brain magnetic resonance imaging
Institution:1. Department of Pediatric Radiology, Clocheville University Hospital, CHRU de Tours, 49, boulevard Béranger, 37044 Tours, France;2. Advanced Clinical Imaging Technology, Siemens Healthcare AG, Switzerland;3. Department of Radiology, University Hospital Lausanne (CHUV), Lausanne, Switzerland;4. LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland;5. Faculty of Medicine, François-Rabelais University, 2, boulevard Tonnellé, 3700 Tours, France
Abstract:Background and purposeAutomated synthetic magnetic resonance imaging (MRI) provides qualitative, weighted image contrasts as well as quantitative information from one scan and is well-suited for various applications such as analysis of white matter disorders. However, the synthesized contrasts have been poorly evaluated in pediatric applications. The purpose of this study was to compare the image quality of synthetic T2 to conventional turbo spin-echo (TSE) T2 in pediatric brain MRI.Materials and methodsThis was a mono-center prospective study. Synthetic and conventional MRI acquisitions at 1.5 Tesla were performed for each patient during the same session using a prototype accelerated T2 mapping sequence package (TAsynthetic = 3:07 min, TAconventional = 2:33 min). Image sets were blindly and randomly analyzed by pediatric neuroradiologists. Global image quality, morphologic legibility of standard structures and artifacts were assessed using a 4-point Likert scale. Inter-observer kappa agreements were calculated. The capability of the synthesized contrasts and conventional TSE T2 to discern normal and pathologic cases was evaluated.ResultsSixty patients were included. The overall diagnostic quality of the synthesized contrasts was non-inferior to conventional imaging scale (P = 0.06). There was no significant difference in the legibility of normal and pathological anatomic structures of synthetized and conventional TSE T2 (all P > 0.05) as well as for artifacts except for phase encoding (P = 0.008). Inter-observer agreement was good to almost perfect (kappa between 0.66 and 1).ConclusionsT2 synthesized contrasts, which also provides quantitative T2 information that could be useful, could be suggested as an equivalent technique in pediatric neuro-imaging, compared to conventional TSE T2.
Keywords:Synthesized brain MRI  Pediatric radiology  Quantitative imaging  Simulated contrast
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号