首页 | 本学科首页   官方微博 | 高级检索  
     


Electrophysiologic target localization in posteroventral pallidotomy
Authors:R. P. Iacono M. D.   F.A.C.S.  J. D. Carlson  S. M. Kuniyoshi  Y. J. Li  A. S. Mohamed  G. Maeda
Affiliation:(1) Movement Disorders and Clinical Neuroscience, Loma Linda University Medical Center, CA, USA;(2) Present address: 11234 Anderson Street, Room 2539, 92354 Loma Linda, CA, USA
Abstract:
Summary The current interest in stereotactic posteroventral pallidotomy (PVP) for treating Parkinson's disease and the variability of published results have raised questions regarding techniques for target localization. In our technique the probe is guided to the optimum target at the most ventral pallidum and ansa lenticularis by macroelectrode stimulation of the internal capsule and optic tract from within the globus pallidus, with the thresholds providing a relative measure of the electrode proximity to these structures. We have characterized these localizing macroelectrode stimulation parameters in 57 posteroventral pallidotomies with consistent anatomic lesion placement, excellent outcome, and no complications.Using a 1.8 × 2.0 mm radiofrequency electrode for macroelectrode stimulation (RFG-3C, Radionics Inc.), minimum voltages (thresholds) to activate motor (at a frequency of 2 Hz) or visual (at a frequency of 100 Hz) responses as well as impedance measurements were obtained at the final target (Tf) and at distances proximal to Tf along the electrode trajectory. The visual and motor threshold voltages at Tf via our standard approach angles (50 ° above base plane, 20 ° from the sagittal plane), had a range of 1.0 to 1.5 V, and 2.0 to 3.5 V respectively. We also found that as the probe approaches Tf there is a significant decrease in voltage thresholds for motor (P<.0001) and visual (P<.0001) responses in an individual patient indicating that the probe is converging on these structures. Increases in impedance between Tf, 2–3 mm, and 4–5 mm proximal to Tf were also statistically significant (P<.0001). Microelectrode recording of electrophysiological neuronal activity at various points along the trajectory towards the target showed distinct firing patters providing identification of the globus pallidus externus and internus, ansa lenticularis, and optic tract.Macroelectrode electrophysiological stimulation within the target volume, inducing threshold responses in the internal capsule and optic tract, provides for accurate localization of the most effective PVP target in the ansa lenticularis. In unresponsive patients, the utilization of microelectrode recording for the identification of the pallidal borders and the optic tract improves safety.
Keywords:Posteroventral pallidotomy  macroelectrode stimulation  microelectrode recording  ansa lenticularis
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号