首页 | 本学科首页   官方微博 | 高级检索  
     


Refinement of CARTO-guided substrate modification in patients with ventricular tachycardia after myocardial infarction
Authors:Li Yi-gang  Wang Qun-shan  Grönefeld Gerian  Israel Carsten  Lu Shang-biao  Shao Yun  Ehrlich Joachim R  Hohnloser Stefan H
Affiliation:1. Department of Cardiology,Xinhua Hospital,School of Medicine,Shanghai Jiaotong University,Shanghai 200092,China
2. Department of Medicine,Division of Cardiology,J. W.Goethe-University,Frankfurt,Germany
Abstract:
BACKGROUND: Substrate modification guided by CARTO system has been introduced to facilitate linear ablation of ventricular tachycardia (VT) after myocardial infarction (MI). However, there is no commonly accepted standard approach available for drawing these ablation lines. Therefore, the aim of the present study was to practically refine this time consuming procedure. METHODS: Substrate modification was performed in 23 consecutive patients with frequent VTs after MI using the CARTO system. The initial target site (ITS) for ablation was identified by pace mapping (PM) during sinus rhythm and/or entrainment pacing (EM) during VT. According to the initial target site, two approaches were used. The initial target site in approach one has a similar QRS morphology as VT and an interval from the stimulus to the onset of QRS complex (S-QRS) of = 50 ms during PM in sinus rhythm or a difference of the post pacing interval and VT cycle length = 30 ms during concealed entrainment pacing of VT; The initial target site in approach two has an similar QRS morphology as VT and an S-QRS of < 50 ms during PM in sinus rhythm. RESULTS: Overall, 50 lines were performed with a length of (35 +/- 11) mm. Procedure time averaged (232 +/- 56) minutes, fluoroscopy time (10 +/- 8) minutes. Sixteen patients were initially involved into approach one. After completion of 3 +/- 1 ablation lines, no further VT was inducible in 13 patients. The remaining 3 patients were switched to use the alternative approach. However, in none of them the alternative approaches were successful. Approach two was initially used in 7 patients. After completion of 3 +/- 1 ablation lines, no further VT was inducible in only 2 patients. The remaining 5 patients were switched to approach one, which resulted in noninducibility of VT in 4 of them. The initial successful rate was significantly higher in the group of approach one compared to that in the group of approach two (13/16 patients vs 2/7 patients, P = 0.026). CONCLUSIONS: The approach for substrate modification of VT after MI can be optimized by identifying the appropriate initial target site with specific characteristics within the zone of slow conduction. The refined approach may facilitate linear ablation of VT, and further reduce the procedure and fluoroscopy time.
Keywords:ventricular tachycardia   mapping   ablation   substrate modification
本文献已被 维普 万方数据 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号