首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of using a Charnley-Howorth enclosure in a district general hospital
Authors:I W Bintcliffe
Abstract:A high rate of infection was found to occur when total hip replacement were performed in an operating theatre used by a variety of surgical specialities. Because of this, a downward displacement laminar flow enclosure was installed to provide ultraclean air operating conditions. Retrospective examination of 419 total hip replacements, carried out over a six-year period during which the enclosure was installed, showed a reduction in the infection rate from 3.2% to 0.4% (P = 0.05) when using the enclosure. The infections were associated with a postoperative wound discharge and with revision surgery but were less frequent when the enclosure was used. Prosthetic loosening was found to be common when metal-to-metal prostheses were used. Working in an enclosure with side panels, wearing body exhaust units, was generally considered to be so noisy as to restrict communication.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号