首页 | 本学科首页   官方微博 | 高级检索  
     


Malignant biliary obstruction: management with percutaneous metallic stent placement
Authors:Brountzos E N  Petropoulos E  Kelekis N L  Magoulas D  Alexopoulou E  Kagianni E  Kelekis D A
Affiliation:Department of Radiology of Eugenidion University Hospital, Athens, Greece. ebrountz@atlas.uoa.gr
Abstract:BACKGROUND/AIMS: To report our experience on palliative management of malignant biliary obstruction with percutaneous placement of metallic stents. METHODOLOGY: During a 3-year period 20 patients with malignant biliary obstruction were treated with percutaneous insertion of metallic biliary endoprostheses. RESULTS: Stent placement was successful in 19 patients, with significant improvement of jaundice in 18 patients. 17 patients have died up to date. In this group survival was 4-324 days (mean: 107 days) and mean stent primary and secondary patency 94.3 and 97.4 days, respectively. Three patients are alive with a follow-up from 20-195 days. Mean secondary patency is 65.3 days (20-134 days). We encountered serious complications in 4 patients (20%). Thirty-day mortality was 15%, while procedural mortality was 10%. Four patients presented 13-120 days (mean: 71.5 days) after the procedure with stent reocclusion (reocclusion rate: 20%). CONCLUSIONS: The procedure is relatively easy and safe to perform, yields excellent palliation of the patient's symptomatology and, therefore, contributes substantially to the maintenance of good quality of life of the patient with malignant biliary obstruction.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号