首页 | 本学科首页   官方微博 | 高级检索  
     

Determination of ribavirin by flow injection chemiluminescence
引用本文:Juqing Jin,Yuhai Tang,Langchong He,Hong Yao,Yuanyuan Sun. Determination of ribavirin by flow injection chemiluminescence[J]. 南京医科大学学报(自然科学版), 2006, 20(5): 266-270
作者姓名:Juqing Jin  Yuhai Tang  Langchong He  Hong Yao  Yuanyuan Sun
作者单位:[1]School of Science . Xi'an Jiaotong University, Xi'an 710061 ,China [2]School of Medicine, Xi'an Jiaotong University, Xi'an 710061 ,China [3]Pharmacy Faculty of Fujian Medical University ,Fuzhou 350004 ,China
摘    要:
Objective: To establish a rapid and precise continuous flow-injection chemiluminescence (CL) method to determine ribavirin. Methods: The ribavirin could restrain strongly CL reaction of luminol in sodium hydroxide (NaOH) solution with potassium chlorate (KClO3). The different experimental parameters affecting the CL intensity were studied carefully. Results: Under optimum conditions (The concentrations of luminol, KClO3, and NaOH were at 0.1 mmol/L, 0.5μmol/L, and 0.2 mol/L, respectively), the linear range of the working curves was 0.01-7.00μg/ml with a detection limit of 0.004μg/ml. Conclusion: The method is simple, rapid and sensitive, and successfully applied to the determination of ribavirin in pharmaceutical preparations and biological fluids.

关 键 词:病毒唑 化学发光 氯酸盐 药物
收稿时间:2006-03-16

Determination of ribavirin by flow injection chemiluminescence
Juqing Jin,Yuhai Tang,Langchong He,Hong Yao,Yuanyuan Sun. Determination of ribavirin by flow injection chemiluminescence[J]. Acta Universitatis Medicinalis Nanjing, 2006, 20(5): 266-270
Authors:Juqing Jin  Yuhai Tang  Langchong He  Hong Yao  Yuanyuan Sun
Abstract:
Objective: To establish a rapid and precise continuous flow-injection chemiluminescence(CL) method to determine ribavirin. Methods: The ribavirin could restrain strongly CL reaction of luminol in sodium hydroxide (NaOH) solution with potassium chlorate(KClO3). The different experimental parameters affecting the CL intensity were studied carefully. Results: Under optimum conditions(The concentrations of luminol,KClO3, and NaOH were at 0.1 mmol/L,0.5 ?mol/L,and 0.2 mol/L, respectively), the linear range of the working curves was 0.01-7.00 g/ml with a detection limit of 0.004 g/ml. Conclusion: The method is simple, rapid and sensitive, and successfully applied to the determination of ribavirin in pharmaceutical preparations and biological fluids.
Keywords:flow injection analysis  chemiluminescence  ribavirin
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《南京医科大学学报(自然科学版)》浏览原始摘要信息
点击此处可从《南京医科大学学报(自然科学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号