首页 | 本学科首页   官方微博 | 高级检索  
     


Robot-assisted coronary artery bypass grafting improves short-term outcomes compared with minimally invasive direct coronary artery bypass grafting
Authors:Wenhui Gong  Junfeng Cai  Zhe Wang  Anqing Chen  Xiaofeng Ye  Haiqing Li  Qiang Zhao
Affiliation:Department of Cardiac Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
Abstract:

Background

Robot-assisted coronary artery bypass grafts (RACAB) utilizing the da Vinci surgical system are increasingly used and allow the surgeon to conveniently harvest internal mammary arteries (IMAs). The aim of this study was to compare the outcomes of off-pump RACAB and minimally invasive direct coronary artery bypass grafting (MIDCAB) in the short and medium term.

Methods

We performed a retrospective review of 132 patients with single- or multiple-vessel coronary artery disease who underwent minimally invasive off-pump CABG (OPCAB) between May 2009 and May 2014. The patients were divided into two groups based on the surgical approach, MIDCAB and RACAB group. The anastomosis of the left internal mammary artery (LIMA) to the left anterior descending artery (LAD) was performed as regular OPCAB through the incision on the beating heart using regular stabilization devices (Genzyme Corporation). The preoperative, intraoperative, postoperative, and follow-up data, including major adverse cardiac and cerebrovascular events (MACCE), were compared.

Results

The preoperative data were similar. RACAB significantly shorten the intensive care unit (ICU) stay and postoperative compared with the MIDCAB group (P<0.05). There were 12 (19.7%) patients treated with a two-stage hybrid procedure in the MIDCAB group and 34 (47.9%) patients in the RACAB group (P=0.001). Thirty-day mortality was 1.6% in the MIDCAB group. There were 9 (14.7%) MIDCAB patients and 2 (2.8%) RACAB patients (P=0.013) that developed new arrhythmia. The two groups showed comparable mid-term survival (P=0.246), but the MACCEs were significantly different (P=0.038).

Conclusions

RACAB may be a valuable alternative for patients requiring single or simple multi-vessel coronary artery bypass grafting (CABG). Although the mid-term mortality outcomes are similar, RACAB improves short-term outcomes and mid-term MACCE-free survival compared with MIDCAB.
Keywords:Minimally invasive direct coronary artery bypass grafting (MIDCAB)   robotically assisted coronary artery bypass grafting (robotically assisted CABG)   coronary surgery   survival
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号