A short-term study of corneal collagen cross-linking with hypo-osmolar riboflavin solution in keratoconic corneas |
| |
Authors: | Shao-Feng Gu Zhao-Shan Fan Li-Hua Wang Xiang-Chen Tao Yong Zhang Chun-Qin Wang Ya Wang Guo-Ying Mu |
| |
Affiliation: | Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China;Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China |
| |
Abstract: |
AIMTo report the 3mo outcomes of collagen cross-linking (CXL) with a hypo-osmolar riboflavin in thin corneas with the thinnest thickness less than 400 µm without epithelium.METHODSEight eyes in 6 patients with age 26.2±4.8y were included in the study. All patients underwent CXL using a hypo-osmolar riboflavin solution after its de-epithelization. Best corrected visual acuity, manifest refraction, the thinnest corneal thickness, and endothelial cell density were evaluated before and 3mo after the procedure.RESULTSThe mean thinnest thickness of the cornea was 408.5±29.0 µm before treatment and reduced to 369.8±24.8 µm after the removal of epithelium. With the application of the hypo-osmolar riboflavin solution, the thickness increased to 445.0±26.5 µm before CXL and recover to 412.5±22.7 µm at 3mo after treatment, P=0.659). Before surgery, the mean K-value of the apex of the keratoconus corneas was 57.6±4.0 diopters, and slightly decreased (54.7±4.9 diopters) after surgery (P=0.085). Mean best-corrected visual acuity was 0.55±0.23 logarithm of the minimal angle of resolution, and increased to 0.53±0.26 logarithm after surgery (P=0.879). The endothelial cell density was 2706.4±201.6 cells/mm2 before treatment, and slightly decreased (2641.2±218.2 cells/mm2) at last fellow up (P=0.002).CONCLUSIONCorneal collagen cross-linking with a hypo-osmolar riboflavin in thin corneas seems to be a promising treatment. Further study should be done to evaluate the safety and efficiency of CXL in thin corneas for the long-term. |
| |
Keywords: | corneal collagen cross-linking keratoconus hypo-osmolar riboflavin thin corneas |
|
| 点击此处可从《国际眼科》浏览原始摘要信息 |
|
点击此处可从《国际眼科》下载免费的PDF全文 |
|