High-resolution proton density weighted three-dimensional fast spin echo (3D-FSE) of the knee with IDEAL at 1.5 Tesla: comparison with 3D-FSE and 2D-FSE--initial experience
Authors:McMahon Colm J  Madhuranthakam Ananth J  Wu Jim S  Yablon Corrie M  Wei Jesse L  Rofsky Neil M  Hochman Mary G
Affiliation:Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA. colmjmcmahon@yahoo.co.uk
Abstract:

Purpose:

To assess the feasibility of combining three‐dimensional fast spin echo (3D‐FSE) and Iterative‐decomposition‐of water‐and‐fat‐with‐echo asymmetry‐and‐least‐squares‐estimation (IDEAL) at 1.5 Tesla (T), generating a high‐resolution 3D isotropic proton density‐weighted image set with and without “fat‐suppression” (FS) in a single acquisition, and to compare with 2D‐FSE and 3D‐FSE (without IDEAL).

Materials and Methods:

Ten asymptomatic volunteers prospectively underwent sagittal 3D‐FSE‐IDEAL, 3D‐FSE, and 2D‐FSE sequences at 1.5T (slice thickness [ST]: 0.8 mm, 0.8 mm, and 3.5 mm, respectively). 3D‐FSE and 2D‐FSE were repeated with frequency‐selective FS. Fluid, cartilage, and muscle signal‐to‐noise ratio (SNR) and fluid‐cartilage contrast‐to‐noise ratio (CNR) were compared among sequences. Three blinded reviewers independently scored quality of menisci/cartilage depiction for all sequences. “Fat‐suppression” was qualitatively scored and compared among sequences.

Results:

3D‐FSE‐IDEAL fluid‐cartilage CNR was higher than in 2D‐FSE (P < 0.05), not different from 3D‐FSE (P = 0.31). There was no significant difference in fluid SNR among sequences. 2D‐FSE cartilage SNR was higher than in 3D FSE‐IDEAL (P < 0.05), not different to 3D‐FSE (P = 0.059). 2D‐FSE muscle SNR was higher than in 3D‐FSE‐IDEAL (P < 0.05) and 3D‐FSE (P < 0.05). Good or excellent depiction of menisci/cartilage was achieved using 3D‐FSE‐IDEAL in the acquired sagittal and reformatted planes. Excellent, homogeneous “fat‐suppression” was achieved using 3D‐FSE‐IDEAL, superior to FS‐3D‐FSE and FS‐2D‐FSE (P < 0.05).

Conclusion:

3D FSE‐IDEAL is a feasible approach to acquire multiplanar images of diagnostic quality, both with and without homogeneous “fat‐suppression” from a single acquisition. J. Magn. Reson. Imaging 2012;361‐369. © 2011 Wiley Periodicals, Inc.
Keywords:magnetic resonance imaging  imaging  three dimensional  knee  joint  musculoskeletal system