首页 | 本学科首页   官方微博 | 高级检索  
     


Transepithelial photorefractive keratectomy mode using SCHWIND-ESIRIS excimer laser: initial clinical results
Authors:Dong-Mei Wang  Yi Du  Guang-Sheng Chen  Liu-Song Tang  Jian-Feng He
Affiliation:Eye Laser Department,Liuzhou Eye Hospital, Liuzhou Red Cross Association Hospital, Liuzhou 545001, Guangxi Zhuang Autonomous Region, China;State Key Laboratory of Ophthalmology,Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China;Eye Laser Department,Liuzhou Eye Hospital, Liuzhou Red Cross Association Hospital, Liuzhou 545001, Guangxi Zhuang Autonomous Region, China;Eye Laser Department,Liuzhou Eye Hospital, Liuzhou Red Cross Association Hospital, Liuzhou 545001, Guangxi Zhuang Autonomous Region, China;Department of Ophthalmology, the First Affiliated Hospital of Guangxi Medical University, Nanning 530021, Guangxi Zhuang Autonomous Region, China
Abstract:
AIM: To evaluate postoperative pain, uncorrected visual acuity (UCVA), and cornea haze value after transepithelial photorefractive keratectomy (T-PRK) performed with aspherical ablation profile using SCHWIND ESIRIS excimer laser.METHODS: Retrospective case series. Fifty-nice eyes (32 patients) with myopia associated with or without astigmatism underwent phototherapeutic keratectomy (PTK) followed by photorefractive keratectomy (PRK) which performed by Optimized Refractive Keratecomy (ORK)-CAM software based on aspherical ablation profile using SCHWIND ESIRIS excimer laser. Postoperative pain scale was measured on a questionnaire through five levels. Haze was graded by five grades, and UCVA, manifest refraction spherical equivalent (MRSE) were analyzed.RESULTS: Mean pain level was (1.37±0.613) (range: 1 to 3), the mean time picking out the soft contact lens was (6.22±1.73) days, at 3 months, UCVA was 1.0 for 40 eyes (67.8%), 0.5 for all eyes (100.0%). The UCVA was significantly less than the preoperative best spectacle corrected visual acuity (BSCVA) (t=-2.84, P=0.006), haze value was (0.27±0.25), no patients had a haze grade up to 2. Mean MRSE was (0.76±0.96) diopter(D) by 3 months.CONCLUSION: The outcomes from this study show that using the SCHWIND ESIRIS aspherical ablation profile for transepithelial PRK has a good visual result. The primary advantage is related to a spherical ablation profile, automatically considers the ablation volume of the stroma and the accurate and smooth removal of the epithelium with PTK. Additional studies are needed to determine long-term outcomes.
Keywords:myopia surgery   transepithelial photorefractive keratectomy   phototherapeutic keratectomy
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号