首页 | 本学科首页   官方微博 | 高级检索  
     


Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens
Authors:Xian-Hui Gong  Qin-Xiang Zheng  Na Wang  Ding Chen  Juan Zhao  Jin Li  Yun-E Zhao
Affiliation:School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325027, Zhejiang Province, China;School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325028, Zhejiang Province, China;School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325029, Zhejiang Province, China;School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325030, Zhejiang Province, China;School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325031, Zhejiang Province, China;School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325032, Zhejiang Province, China;School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou 325033, Zhejiang Province, China
Abstract:

AIM

To compare the visual and optical performance of eyes with different corneal spherical aberration (SA) implanted with spherical aberration-free intraocular lens (IOLs).

METHODS

Thirty-six patients with different corneal SA had phacoemulsification with implantation of spherical aberration-free IOLs. Patients were divided into 3 groups according to the value of preoperative corneal SA. Eyes with corneal SA <0.10µm were assigned to group A, those with 0.10 ≤corneal SA <0.20µm to Group B, and those with 0.20≤ corneal SA <0.35µm to Group C. Best-corrected visual acuity (BCVA), contrast sensitivity, corneal SA, total ocular aberrations, and depth of focus were recorded 3 months postoperatively. Distance-corrected near and intermediate visual acuity was studied to measure depth of focus.

RESULTS

BCVA and contrast sensitivity were similar between groups. There were no significant differences in distance-corrected near or intermediate visual acuity. Corneal SA was similar before and 3 months after surgery in the 3 groups. With a 5.0mm pupil diameter, root mean square values for total ocular higher-order aberrations (HOAs) were lower in groups A and B than in group C. Total ocular SA was lower in group A than in groups B and C. SA was also lower in group B than in group C. Coma and trefoil were similar between the groups.

CONCLUSION

Implantation of spherical aberration-free IOLs in eyes with different corneal SA results in similar visual performance at BCVA, contrast sensitivity and depth of focus.
Keywords:spherical aberration-free intraocular lens   sherical aberration   contrast sensitivity   cataract
本文献已被 PubMed 等数据库收录!
点击此处可从《国际眼科》浏览原始摘要信息
点击此处可从《国际眼科》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号