利用Test-Bolus技术分析影响颈动脉CT增强效果的个体因素
引用本文:黄刚,马娅琼,李生虎.利用Test-Bolus技术分析影响颈动脉CT增强效果的个体因素[J].中国医学影像技术,2013,29(6):1015-1018.
作者姓名:黄刚  马娅琼  李生虎
作者单位:甘肃省人民医院放射科, 甘肃 兰州 730030;甘肃省人民医院放射科, 甘肃 兰州 730030;无锡市中医医院放射科, 江苏 无锡 214000
摘    要:目的 利用Test-Bolus技术分析行颈总动脉CTA检查时对比剂到达颈总动脉的达峰时间和峰值与个体因素之间的关系。 方法 对94例患者采用Test-Bolus技术行颈总动脉CTA检查,分析颈总动脉的时间-密度曲线,获得其达峰时间和峰值。采用单因素回归分析和多因素逐步回归法分析患者性别、年龄、身高等个体因素与对比剂到达颈总动脉的达峰时间和峰值的关系。 结果 根据患者个体相关因素得出多元回归方程:达峰时间(s)=-5.14+2.33×性别+0.07×年龄+0.08×身高(cm)+0.05×平均动脉压(mmHg);峰值(HU)=453.87-2.28×体质量(kg)-2.41×达峰时间(s)-0.63×心率。 结论 行颈动脉CTA前应首先评估患者的个体因素,根据达峰时间和峰值的多元回归方程,可计算出注射对比剂后的延迟时间和峰值。

关 键 词:体层摄影术  X线计算机  颈动脉  达峰时间  峰值  个体因素
收稿时间:2012/11/23 0:00:00
修稿时间:2013/3/26 0:00:00

Analysis of individual impact factors on the enhancement effect of carotid CTA with Test-Bolus technology
HUANG Gang,MA Ya-qiong and LI Sheng-hu.Analysis of individual impact factors on the enhancement effect of carotid CTA with Test-Bolus technology[J].Chinese Journal of Medical Imaging Technology,2013,29(6):1015-1018.
Authors:HUANG Gang  MA Ya-qiong and LI Sheng-hu
Institution:Department of Radiology, Gansu Provincial Hospital, Lanzhou 730030, China,;Department of Radiology, Gansu Provincial Hospital, Lanzhou 730030, China,;Department of Radiology, Wuxi Traditional Medicine Hospital, Wuxi 214000, China
Abstract:Objective To explore the individual impact factors on the time to peak (TTP), the peak value (POV) of contrast agent during carotid artery CTA with Test-Bolus technology. Methods Ninety-four patients underwent common carotid artery CTA with Test-Bolus technology, then the time-density curves (TDC) were analyzed to obtain TTP and POV. Single-factor regression analysis and multivariate stepwise regression analysis were used to analyze the relationship between individual factors (such as gender, age, body height, et al) and TTP, POV, respectively. Results Two multiple regression equations were obtained, TTP (s)=-5.14+2.33×G (gender)+0.07×A (age)+0.08×BH (body height, cm)+0.05×MAP (mean arterial pressure, mmHg), POV (HU)=453.87-2.28×BW (body weight, kg)-2.41×TTP(s)-0.63×HR (heart rate). Conclusion The appropriate delay time and POV after injecting contrast agent can be obtained according to individual factors and multiple regression equations in carotid CTA.
Keywords:Tomography  X-ray computed  Carotid  Time to peak  Peak value  Individual factors