首页 | 本学科首页   官方微博 | 高级检索  
     

Matrix栓塞颅内动脉瘤的影像学随访
引用本文:Zhao ZW,Deng JP,Gao GD. Matrix栓塞颅内动脉瘤的影像学随访[J]. 中华医学杂志, 2007, 87(1): 37-40
作者姓名:Zhao ZW  Deng JP  Gao GD
作者单位:710038,西安,第四军医大学唐都医院神经外科
摘    要:
目的 通过随访方式确定Matrix弹簧圈栓塞颅内动脉瘤后影像学变化,评定Matrix防止颅内动脉瘤栓塞后再通的效果及可能的影响因素。方法 针对应用Matrix弹簧圈栓塞的48例颅内动脉瘤患者,在局麻下行脑血管造影,常规取正位、侧位和栓塞工作位。对比栓塞后即刻影像和随访影像。结果 48例患者共49枚动脉瘤接受脑血管造影随访,平均随访时间11.75个月。栓塞后即刻造影和复查造影:完全栓塞率分别为34.7%和53.1%,次全栓塞率分别为42.9%和24.5%。不全栓塞率分别为22.4%和22.4%。共14枚动脉瘤发生再通,再通率为28.5%,严重再通率14.3%。结论 Matrix栓塞颅内动脉瘤后影像比较稳定,再通率不高于GDC等裸金属圈栓塞的动脉瘤。

关 键 词:颅内动脉瘤 栓塞 脑血管造影
修稿时间:2006-05-24

Angiographic outcomes of cerebral aneurysms embolized with Matrix coils
Zhao Zhen-Wei,Deng Jian-Ping,Gao Guo-Dong. Angiographic outcomes of cerebral aneurysms embolized with Matrix coils[J]. Zhonghua yi xue za zhi, 2007, 87(1): 37-40
Authors:Zhao Zhen-Wei  Deng Jian-Ping  Gao Guo-Dong
Affiliation:Department of Neurosurgery, Tangdu Hospital, Fourth Military Medical University, Xi'an, China.
Abstract:
OBJECTIVE: To investigate the effect of Matrix coil in prevention of recanalization of intracranial aneurysm after embolization with Matrix coils. METHODS: Plan of follow-up was designed to make digital substraction angiographies for Forty-eight intracranial aneurysm patients with 49 aneurysm s, 22 males and 26 females, aged 52 (15 ~ 67), underwent embolization with Matrix coil and were followed up for 11.75 months on average. Digital substraction angiography was conducted immediately after the operation and during the follow-up. At least three projections, including anterior-posterior projection, lateral projection, and optimal working projection were adopted. The percentages of occlusion of the initial and the follow-up images were compared. RESULTS: DSA immediately after the opearion showed a complete occlusion rate of 34.7%, near complete rate of 42.9% and an incomplete rate of 22.4%. The follow-up DSA revealed that the complete occlusion rate was 53.1%, near complete rate was 24.5%, and incomplete rate was 22.4%. The overall recanalization rate was 28.5%, 22.2% for small aneurysms and 46.1% for large aneurysms. The major recanalization rate was 14.3% and the improvement rate was 24.5%. The recanalization rate was 11.8% for total occlusion, 33.3% for near complete occlusion, and 45.5% for incomplete. CONCLUSION: The long-term angiographic outcome of intracranial aneurysms after embolization with Matrix coils is stable. The recanalization rate is acceptable and is not better than that of GDCs.
Keywords:Cerebral aneurysm   Embolization    Angiography
本文献已被 维普 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号