首页 | 本学科首页   官方微博 | 高级检索  
     

核素心肌灌注显像定量分析技术诊断本地人群冠心病的价值
引用本文:黎东,李殿富,冯建林,袁冬兰,赵中强,周艳丽,陈建玉,曹克将. 核素心肌灌注显像定量分析技术诊断本地人群冠心病的价值[J]. 中华核医学杂志, 2010, 30(4): 295-299. DOI: 10.3760/cma.j.issn.0253-9780.2010.05.004
作者姓名:黎东  李殿富  冯建林  袁冬兰  赵中强  周艳丽  陈建玉  曹克将
作者单位:南京医科大学第一附属医院、江苏省人民医院心内科,210029;南京医科大学第一附属医院、江苏省人民医院核医学科,210029;
基金项目:江苏省医学重点学科(实验室)江苏省人民医院心血管病临床医学中心开放课题江苏省"六大人才高峰"第五批高层次人才项目
摘    要:Objective To evaluate the accuracy of automated quantification of myocardial perfusion imaging (MPI) using a method based on a Western normal database for the detection of coronary artery disease (CAD) in a group of Chinese patients. Methods Seventy-two Chinese patients who underwent coronary angiography (CAG) and MPI within 3 months were recruited into this study. Eighty selected from 140 Chinese patients with low probability of CAD ( < 5% ) were enrolled into local normal database of 99Tcm-methoxyisobutylisonitrile (MIBI) MPI using Cedars quantitative perfusion SPECT (QPS) database. Two Western MPI normal databases (CSMC MibiMbiAuto and Mibimibi) were used for processing the Chinese CAD patients recruited in this study, and the results were compared with those using local normal database and visual interpretation. T-test and z-test were used for statistical analysis. Results The extent (EXT)measurement obtained from Mibimibi and local database was ( 10.73 ± 14.54)% and ( 14.22 ± 16.51 )%,respectively ( t = 7.87, P < 0.001 ); the severity (SEV) was 1.07 ± 0.93 and 1.34 ± 1.20, respectively ( t =7.45, P<0.001). The area under curve(AUC) by using EXT measurement for local database (0.85 ±0.05) was larger than that for CSMC MibiMbiAuto ( AUC = 0.72 ± 0.06, z = 2.50, P < 0.01 ) and Mibimibi ( AUC = 0.77 ± 0.06, z = 2.47, P = 0.014). The AUC of local database showed no significant difference from that of visual interpretation (AUC=0.83 ±0.05, z=0.05, P>0.05). Conclusion Quantification of MPI of our Chinese patients using Western normal database would decrease the accuracy for the detection of CAD.

关 键 词:冠状动脉疾病   中国   体层摄影术,发射型计算机,单光子   

The accuracy of myocardial perfusion imaging using quantitative analysis for patients with coronary artery disease: a Chinese hospital experience
LI Dong,LI Dian-fu,FENG Jian-lin,YUAN Dong-lan,ZHAO Zhong-qiang,ZHOU Yan-li,CHEN Jian-yu,CAO Ke-jiang. The accuracy of myocardial perfusion imaging using quantitative analysis for patients with coronary artery disease: a Chinese hospital experience[J]. Chinese Journal of Nuclear Medicine, 2010, 30(4): 295-299. DOI: 10.3760/cma.j.issn.0253-9780.2010.05.004
Authors:LI Dong  LI Dian-fu  FENG Jian-lin  YUAN Dong-lan  ZHAO Zhong-qiang  ZHOU Yan-li  CHEN Jian-yu  CAO Ke-jiang
Abstract:
Keywords:MIBICoronary diseaseChinaTomography  emission-computed  single-photonMIBI
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号