首页 | 本学科首页   官方微博 | 高级检索  
     


Revision total hip replacement using cemented collarless double-taper femoral components
Authors:Howie D W  Wimhurst J A  McGee M A  Carbone T A  Badaruddin B S
Affiliation:Department of Orthopaedics and Trauma, Royal Adelaide Hospital, University of Adelaide, Adelaide, SA 5000, Australia. donald.howie@adelaide.edu.au
Abstract:
We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up. Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain. Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏