首页 | 本学科首页   官方微博 | 高级检索  
     


Relationship Between CT Volumetry and Functional Liver Volume Using Technetium-99m Galactosyl Serum Albumin Scintigraphy in Patients Undergoing Preoperative Portal Vein Embolization Before Major Hepatectomy: A Preliminary Study
Authors:Atsushi Nanashima MD  Hiroyuki Yamaguchi MD  Shinichi Shibasaki MD  Shigeyuki Morino MD  Noboru Ide MD  Hiroaki Takeshita MD  Takashi Tsuji MD  Terumitsu Sawai MD  Tohru Nakagoe MD  Takeshi Nagayasu MD  Youji Ogawa MD
Affiliation:(1) Division of Surgical Oncology, Department of Translational Medical Sciences, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki 852-8501, Japan;(2) Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
Abstract:
To clarify the relationship between morphological measurements of hepatic volume by computed tomography (CT-vol) and functional volume (RI-vol) by technetium-99m galactosyl human serum albumin (99mTc-GSA) scintigraphy, and its clinical significance, we examined 16 patients with a background liver status of either normal liver function (n = 4), chronic hepatitis or cirrhosis (n = 7), or obstructive jaundice (n = 5). In five patients who underwent preoperative portal vein embolization (PVE), volumetric measurement was performed 2 weeks after PVE. The mean values of CT-vol and RI-vol of the right lobe were 692± 147 cm3 (66.1 ± 10.7%) and 668 ± 159 cm3 (67.8 ± 13.2%), respectively, and those of the left lobe were 329 ± 138 cm3 (33.9 ± 10.6%) and 328± 170 cm3 (32.2 ± 13.2%), respectively. There were no significant differences in the volume measurements between the two volumetric techniques. Correlations between CT-vol and RI-vol in the right and left lobes were positive and significant (r = 0.912 and 0.903, respectively; both P′s < 0.001). The mean values of post-PVE CT-vol and RI-vol of the right lobe in five patients were significantly different (628 ± 149 and 456± 211 cm3, respectively; P = 0.033). However, the mean values of post-PVE CT-vol and RI-vol of the left lobe were not different (496 ± 124 and 483± 129 cm3, respectively). We propose that volumetric measurement by 99mTc-GSA scintigraphy is useful for detecting changes in functional volume of individual lobes of the liver and is a more dynamic method compared with detection of morphological changes by CT scan. No financial support was received from any source for this study.
Keywords:liver resection  technetium-99m galactosyl human serum albumin liver scintigraphy  functional volume  CT volumetry  portal vein embolization
本文献已被 PubMed SpringerLink 等数据库收录!