首页 | 本学科首页   官方微博 | 高级检索  
     


Transcatheter closure of inferior sinus venosus defect using a patent ductus arteriosus occluder following simulation with a 3D-printed model
Authors:Zeming Zhou  Yuanrui Gu  Hong Zheng  Huijun Song  Shiguo Li  Chaowu Yan  Zhongying Xu
Abstract:
BackgroundTranscatheter closure of inferior sinus venosus defect (ISVD) is still contraindication. To explore whether transcatheter closure with patent ductus arteriosus (PDA) occluders is possible for ISVD.MethodsFrom June 2014 to March 2021, 12 patients were recruited diagnosed as <25 mm ISVD. The three-dimensional printing (3DP) heart model was produced based on multi-slice computed tomography (MSCT) scans. Preoperative closure simulation was planned on the personalized 3D model for each patient. Follow-up including electrocardiography (ECG), transthoracic echocardiography (TTE), and X-ray was traced.Results3DP models of 12 patients were successfully printed. Twelve patients had been diagnosed with <25 mm ISVD and 4 of them had another secundum atrial septal defect (ASD). All patients were produced interventional therapy successfully. PDA occluder was implanted to closed ISVD, and ASD was closed using ASD occluder simultaneously. The average diameter of ISVD measured by TTE was (12.67±3.80), and the average diameter of sagittal axes and longitudinal axes measured by the 3D-printed model was (17.08±3.20) and (18.42±4.62) mm, respectively. The average size of PDA (diameter of pulmonary artery side) was (28.17±3.35) mm. Compared with the preoperative, the X-ray cardiothoracic ratio (0.51±0.04 vs. 0.47±0.06, P=0.007) and the right ventricle anterior-posterior diameter (31.17±5.65 vs. 24.58±3.75 mm, P<0.001) of postoperative was significantly decreased. During the average (47.75±27.52) months follow-up, it has achieved satisfying results, and there were no severe adverse events such as device transposition, death, and pericardial tamponade occurred.ConclusionsAssisting by 3D heart model, transcatheter closure of ISVD with PDA occluder had an excellent outcome. This method provides a new considerable treatment strategy for ISVD.
Keywords:Three-dimensional printing (3DP)   inferior sinus venosus defect (ISVD)   interventional therapy   patent ductus arteriosus occluder (PAD occluder)
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号