基于中国儿童参考体模的X射线摄影剂量评估
引用本文:马锐垚,邱睿,任丽,武祯,胡安康,李君利,李春艳,刘海宽,卓维海. 基于中国儿童参考体模的X射线摄影剂量评估[J]. 中华放射医学与防护杂志, 2021, 41(5): 363-367
作者姓名:马锐垚  邱睿  任丽  武祯  胡安康  李君利  李春艳  刘海宽  卓维海
作者单位:清华大学工程物理系 粒子技术与辐射成像教育部重点实验室, 北京 100084;同方威视技术股份有限公司, 北京 100084;复旦大学放射医学研究所, 上海 200032
基金项目:国家自然科学基金(11875036)
摘    要:
目的:建立中国儿童面元参考体模,并将其应用于儿童X射线摄影的剂量评估中。方法:基于不同年龄儿童的CT原始数据,经过器官勾画、器官调整优化等过程建立起5和10岁的中国儿童面元参考体模。基于上述体模,利用蒙特卡罗方法,对X射线摄影进行建模,计算不同照射条件下儿童受检者器官剂量转换系数及有效剂量转换系数。结果:建立的5和10...

关 键 词:儿童体模  X射线摄影  蒙特卡罗  辐射剂量
收稿时间:2020-12-17

Dose estimation of X-ray radiography based on Chinese pediatric reference phantoms
Ma Ruiyao,Qiu Rui,Ren Li,Wu Zhen,Hu Ankang,Li Junli,Li Chunyan,Liu Haikuan,Zhuo Weihai. Dose estimation of X-ray radiography based on Chinese pediatric reference phantoms[J]. Chinese Journal of Radiological Medicine and Protection, 2021, 41(5): 363-367
Authors:Ma Ruiyao  Qiu Rui  Ren Li  Wu Zhen  Hu Ankang  Li Junli  Li Chunyan  Liu Haikuan  Zhuo Weihai
Affiliation:Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, China;Nuctech Company Limited, Beijing 100084, China;Institute of Radiation Medicine, Fudan University, Shanghai 200032, China
Abstract:
Objective The Chinese pediatric mesh-type reference phantoms were developed and applied in the dose assessment of X-ray radiography. Methods The 5- and 10-year-old Chinese pediatric mesh-type reference phantoms were developed based on the CT data. Based on the phantoms, the Monte Carlo method was applied to simulate the X-ray radiography to calculate the organ dose conversion coefficient and the effective dose conversion coefficient in different radiography conditions. Results The 5- and 10-year-old Chinese pediatric mesh-type reference phantoms were developed, and the physical parameters were consistent with the national standard. The differences of the organ mass between the established phantoms and reference data were within 2%. The database of the pediatric chest posteroanterior projection and abdominal anteroposterior projection,tube voltage 60-90 kVp, total filtration 2.5~4 mmAl were simulated, and the difference between the effective dose conversion factor and the literature result was within 3%. Conclusions The established Chinese pediatric mesh-type reference phantoms can be applied in the studies of radiation protection and clinical medicine and their result can provide an important reference for the dose assessment of the pediatric X-ray radiography.
Keywords:Pediatric phantom  X-ray radiography  Monte Carlo  Radiation dose