Distinguishability for magnetic resonance-electrical impedance tomography (MR-EIT) |
| |
Authors: | Altunel Haluk Eyüboğlu B Murat Köksal Adnan |
| |
Affiliation: | Department of Electrical and Electronics Engineering, Middle East Technical University, 06531 Ankara, Turkey. |
| |
Abstract: | A distinguishability measure is defined for magnetic resonance-electrical impedance tomography (MR-EIT) based on magnetic flux density measurements. This general definition is valid for 2D and 3D structures of any shape. As a specific case, a 2D cylindrical body with concentric inhomogeneity is considered and a bound of the distinguishability is analytically formulated. Distinguishabilities obtained with potential and magnetic flux density measurements are compared. |
| |