首页 | 本学科首页   官方微博 | 高级检索  
     


Transcatheter closure of a complex postmyocardial infarction ventricular septal defect after surgical patch dehiscence
Authors:Cutfield N J  Ruygrok P N  Wilson N J  Raudkivi P J  Greaves S C  Gentles T L  Kerr A J
Affiliation:Department of Cardiology, Green Lane Hospital, Auckland, New Zealand.
Abstract:
Ventricular septal defect (VSD) complicating acute myocardial infarction is a rare but serious event carrying a high mortality. Residual shunting after emergency surgical repair is common, adversely affects prognosis and can necessitate reoperation. We describe the successful transcatheter VSD closure with the Amplatzer occluder in a 75-year old man after earlier emergency surgical repair of a VSD complicating an acute myocardial infarction. The technique and positioning of the device in a tortuous infero-apical VSD are described.
Keywords:ventricular septal defect    myocardial infarction    transcatheter closure    Amplatzer device
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏