首页 | 本学科首页   官方微博 | 高级检索  
     


Screw oversizing for anterior cruciate ligament graft fixation in primary and enlarged tibial tunnels: A biomechanical study in a porcine model
Authors:Martin Eichinger  Werner Schmoelz  René Attal  Armin Moroder  Christian Heinz Heinrichs  Vinzenz Smekal  Raul Mayr
Affiliation:1. Department of Trauma Surgery, Medical University of Innsbruck, Innsbruck, Austria;2. Department of Trauma Surgery and Sports Traumatology, Academic Hospital Feldkirch, Feldkirch, Austria;3. AUVA Trauma Centre Klagenfurt, Klagenfurt, Austria
Abstract:

Background

Ideal diameter for tibial interference screw fixation of the anterior cruciate ligament (ACL) graft remains controversial. Tibial graft fixation with screws matching the tunnel diameter vs. one-millimetre oversized screws were compared.

Methods

In 32 cadaveric porcine tibiae, bovine extensor tendons with a diameter of eight millimetres were fixed in (I) a primary ACL reconstruction scenario with eight-millimetre tibial tunnels (pACL), with eight-millimetre (pACL-8) vs. nine-millimetre (pACL-9) screws, and (II) a revision ACL reconstruction scenario with enlarged tunnels of 10?mm (rACL), with 10-mm (rACL-10) vs. 11-mm (rACL-11) screws. Specimens underwent cyclic loading with low and high load magnitudes followed by a load-to-failure test. Graft slippage and ultimate failure load were recorded.

Results

In comparison with matched-sized screws (pACL-8), fixation with oversized screws (pACL-9) showed with significantly increased graft slippage during cyclic loading at higher load magnitudes (1.19?±?0.23 vs. 1.98?±?0.67?mm; P?=?0.007). There were no significant differences between the two screw sizes in the revision scenario (rACL-10 vs. rACL-11; P?=?0.38). Graft fixation in the revision scenario resulted in significantly increased graft slippage in comparison with fixation in primary tunnels at higher loads (pACL vs. rACL; P?=?0.004). Pull-out strengths were comparable for both scenarios and all screw sizes (P?>?0.316).

Conclusions

Matched-sized interference screws provided better ACL graft fixation in comparison with an oversized screw diameter. In revision cases, the fixation strength of interference screws in enlarged tunnels was inferior to the fixation strength in primary tunnels.
Keywords:Anterior cruciate ligament  ACL reconstruction  Revision ACL reconstruction  Interference screw  Oversizing  Biomechanics