首页 | 本学科首页   官方微博 | 高级检索  
     

64层螺旋CT冠状动脉成像定位像CT值与管电流关系的研究
引用本文:高建华,李涛,李剑颖,米丰岗,李娜,崔英,戴汝平. 64层螺旋CT冠状动脉成像定位像CT值与管电流关系的研究[J]. 中华放射学杂志, 2001, 43(1): 719-724. DOI: 10.3760/cma.j.issn.1005-1201.2009.07.015
作者姓名:高建华  李涛  李剑颖  米丰岗  李娜  崔英  戴汝平
作者单位:武警总医院CT科,北京,100039;GE中国CT影像研究室;中国医学科学院北京协和医学院阜外心血管病医院放射科;
摘    要:
Objective To characterize the association between the mean CT value on a scout view and the dependent mA selection method, and to evaluate the clinical value of a mA selection method based on scout view mean CT value in obtaining individualized scan protocol and consistent image quality for patient population on 64-row MSCT CT coronary angiography (CTCA).Methods One hundred patients (group A) underwent CCTA consecutively using standard protocol with a fixed mA.The mean CT value of a fixed ROI (region of interest) from the scout AP view and the CTCA image noise (standard deviation on the root of ascending aorta) were measured.The correlation between CT values and noise was studied establish a formula and a list to determine the required mA for obtaining a consistent CTCA image noise based on the measured SV CT value.Another 100 patients (group B) were scanned using the same parameters as group A except the mA and the CT value was also measured.The mA was determined by the list established previously.The CTCA image quality (IQ) as well as the image noise (IN) and the effective dose (ED) from the two groups were statistically analyzed using t-test.The CT findings for the 32 patients in the group B were also compared with the selective coronary angiography (SCA) results.The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of CCTA for detection of significant stenosis were obtained.Results The formula between the required mA and the CT value was : XmA=FmA×[(K1×CTscout + C1)/INa]2.The CCTA images in B group had statistically higher IN (27.66±2.57,22.22±4.17,t=11.33, P=0.000), but no statistical difference between IQ scores for the two groups (3.29±0.66,3.37±0.67,t=0.009, P=0.990), and ED[(8.72±2.51) versus (12.53±0.90) mSv]was 30% lower for the B group (P<0.01).For the 32 patients in the B group who had SCA, the CCTA sensitivity, specificity, positive predictive value, negative predictive value, and stenosis detection accuracy were 94.92% (56/59), 92.13% (82/89) ,88.89% (56/63) ,96.47% (82/85) and 93.24% (138/148) wspectively for stenosis greater than 50%.Conclusion The mA selection method based on the SV CT value for CCTA in 64-row MSCT provides individualized protocol to obtain consistent image quality and to optimize dose delivery to patients.

关 键 词:冠状血管   体层摄影术,X线计算机   辐射剂量   质量控制   

Association between the mean CT value on a scout view and the dependent mA selection method in coronary artery imaging on 64-row multi-slice spiral CT
GAO Jian-hua,LI Tao,LI Jian-ying,MI Feng-gang,LI Na,CUI Ying,DAI Ru-ping. Association between the mean CT value on a scout view and the dependent mA selection method in coronary artery imaging on 64-row multi-slice spiral CT[J]. Chinese Journal of Radiology, 2001, 43(1): 719-724. DOI: 10.3760/cma.j.issn.1005-1201.2009.07.015
Authors:GAO Jian-hua  LI Tao  LI Jian-ying  MI Feng-gang  LI Na  CUI Ying  DAI Ru-ping
Abstract:
Keywords:Coronary vesselsTomography  X-ray computedRadiation dosageQuality control