首页 | 本学科首页   官方微博 | 高级检索  
     


Magnetic resonance imaging to assess acute changes in atrial and ventricular parameters after transcatheter closure of atrial septal defects
Authors:Burgstahler Christof  Wöhrle Jochen  Kochs Matthias  Nusser Thorsten  Löffler Christine  Kunze Markus  Höher Martin  Gawaz Meinrad P  Hombach Vinzenz  Merkle Nico
Affiliation:Cardiology Division, Department of Internal Medicine III, University of Tübingen, Tübingen, Germany.
Abstract:PURPOSE: To evaluate acute changes in atrial and ventricular parameters by the use of cardiac magnetic resonance imaging (MRI) in patients with percutaneous transcatheter atrial septal defects (ASD) closure. MATERIALS AND METHODS: The study included 14 patients (six males and eight females, 45 +/- 18 years) with congenital ASD. Cardiac MRI (1.5T Philips Intera CV) was performed before and within 24 hours after transcatheter ASD closure. Right atrial (RA) and left atrial (LA) dimensions, as well as right (RV) and left (LV) ventricular end-diastolic (ED) volumes were determined. Atrial size was assessed by planimetry of the maximum RA and LA areas in a standard four-chamber view, and ventricular volumes were calculated according to a modified Simpson's rule in short-axis views. RESULTS: The mean RA decreased significantly from 27.6 +/- 6.4 cm(2) before closure to 24.4 +/- 5.6 cm(2) after the procedure (P = 0.0018), whereas the LA area did not change (24.1 +/- 4.7 cm(2) vs. 23.8 +/- 5.2 cm(2), P = 0.76). The RV volumes, volume index, and ejection fraction (EF) decreased significantly from 229 +/- 64 mL to 181 +/- 43 mL (P < 0.001, average reduction = 19% +/- 15%), from 126.0 +/- 37.2 mL/m(2) to 96.6 +/- 28.6 mL/m(2) (P < 0.0001) and from 64 +/- 5% to 58% +/- 7% (P = 0.01), respectively. The LV volumes and volume index remained unchanged (114 +/- 25 mL vs. 118 +/- 22 mL, P = 0.18, 63.5 +/- 13.5 mL/m(2) vs. 63.0 +/- 17.4 mL/m(2), P = 0.83). Left-right shunting decreased from 40% +/- 15% to 9% +/- 15% (P < 0.001). CONCLUSION: Cardiac MRI can reveal detailed information on acute changes in shunt fraction and ventricular dimensions after ASD closure. ASD closure by percutaneous transcatheter device implantation results within 24 hours in a significant reduction of shunt fraction, RA and RV sizes, and RV function, whereas LA and LV dimensions remain unchanged.
Keywords:magnetic resonance imaging  atrial septal defect  occluder  shunt  device
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号