Cure performance of light-activated composites by differential thermal analysis (DTA)
Authors:Dr.J.F. McCabe
Affiliation:Dental Materials Science Unit, University of Newcastle upon Tyne, Dental School, Newcastle upon Tyne, NE2 4BW, England
Abstract:
A technique which utilizes differential thermal analysis and a divided fibre optic system is a valuable aid to the study of the curing behaviour of lightactivated composites. Degree of cure and temperature rise can readily be evaluated as a function of irradiation time. Shade of material, thickness, sample temperature and the presence of porosity all have a significant effect on cure behaviour. The temperature rise for a 60 mm3 sample of material varies between 20°C and 40°C for the materials tested.
Keywords:composite resins   thermal analysis   irradiation   curing   degree of polymerization