Simulation of tagged MR images with linear tetrahedral solid elements |
| |
Authors: | Truscott K J Buonocore M H |
| |
Affiliation: | Biomedical Engineering Graduate Group, University of California, Davis, CA, USA. |
| |
Abstract: | Computer simulation of tagged magnetic resonance (MR) images is presented using signals derived from connected solid triangular or tetrahedral elements. Simulation provides precisely-known deformations for validating tag quantification algorithms. MR imaging signal is derived by Fourier-transforming over a standard element, then mapping to actual elements via transformations. Linear intensity variations over the element are interpolated from vertex intensities determined by tag calculations. |
| |
Keywords: | MRI magnetic resonance imaging simulation tagging deformation grid analysis |