BACE1抑制剂分子水平高通量筛选体系的建立
引用本文:周金武,程肖蕊,程军平,周文霞,张永祥.BACE1抑制剂分子水平高通量筛选体系的建立[J].国外医学(药学分册),2010(4):302-309.
作者姓名:周金武  程肖蕊  程军平  周文霞  张永祥
作者单位:军事医学科学院毒物药物研究所三室,北京100850
基金项目:国家科技重大专项——综合性新药研究开发技术大平台资助项目(2009zx09502-017); 国家自然科学基金资助项目(90709012、30772562、30973541); 国家重点基础研究发展计划(973计划)资助项目(2004CB518907); 国家高技术研究与发展计划(863计划)资助项目(2008AA02Z423)
摘    要:目的建立体外分子水平β-分泌酶(BACE1)抑制剂高通量筛选体系。方法采用均相时间分辨荧光法(HTRF),通过优化反应时间、酶浓度、检测仪器等实验条件,建立BACE1抑制剂高通量筛选体系,根据待测样品对BACE1活性抑制程度筛选其抑制剂。结果采用HTRF法建立了BACE1抑制剂高通量筛选体系,其中反应时间确定为6h、BACE1浓度为670U/L,采用VICTOR3酶标仪测得信噪比为649.6,信背比为44.6,Z′因子为0.91,变异系数小于10%,并筛选到一系列IC50小于10-6mol/L的化合物。结论采用HTRF法建立的BACE1抑制剂筛选体系灵敏度高、特异性和稳定性好,可用于BACE1抑制剂的高通量筛选。

关 键 词:β分泌酶  BACE1抑制剂  均相时间分辨荧光  高通量筛选  Z′因子

Establishment of high-throughput screening system for BACE1 inhibitors in vitro
ZHOU Jin-wu,CHENG Xiao-rui,CHENG Jun-ping,ZHOU Wen-xia,ZHANG Yong-xiang.Establishment of high-throughput screening system for BACE1 inhibitors in vitro[J].Foreign Medical Sciences(Section of Pharmarcy),2010(4):302-309.
Authors:ZHOU Jin-wu  CHENG Xiao-rui  CHENG Jun-ping  ZHOU Wen-xia  ZHANG Yong-xiang
Institution:(Institute of Pharmacology and Toxicology,Academy of Military Medical Sciences,Beijing 100850,China)
Abstract:Objective To establish the high-throughput screening system for β-secretase(β-site amyloid precursor protein cleaving enzyme 1,BACE1)inhibitors in vitro.Methods Using the homogeneous time-resolved fluorescence(HTRF) technique to establish a high-throughput screening system for BACE1 inhibitors according to the extent that test compounds inhibited BACE1 activity by optimizing the incubation time,enzyme concentration and the detector.Results A high-throughput screening system for BACE1 inhibitors based on HTRF methods was established.The incubation time was 6 h,the BACE1 concentration is 670 U/L.According to the detector of VICTOR3,the signal-to-noise(S/N) ratio reached 649.6,while the signal-to-background(S/B) ratio and Z' factor were 44.6 and 0.91,respectively.The coefficient of variation(CV) was much lower than 10%.Using this method,the inhibitors with IC5010-6mol/L could be screened out.Conclusion The high-throughput screening system based on HTRF Could assure a high sensitivity,specificity and stability,which could be used to high-through put screening for the BACE1 inhibitors.
Keywords:β-secretase  BACE1 inhibitor  homogeneous time-resolved fluorescence  high-throughput screening  Z' factor