首页 | 本学科首页   官方微博 | 高级检索  
     

彩色多普勒超声诊断急性下肢深静脉血栓形成的临床价值
引用本文:王娟,王蔚蔚,熊娟. 彩色多普勒超声诊断急性下肢深静脉血栓形成的临床价值[J]. 临床超声医学杂志, 2011, 13(4): 258-260
作者姓名:王娟  王蔚蔚  熊娟
作者单位:南京医科大学第二附属医院特检科,南京市,210011
摘    要:目的 探讨彩色多普勒超声(CDUS)在急性下肢深静脉血栓形成诊断中的应用价值及限制因素.方法 应用彩色多普勒超声仪对52例疑有急性下肢深静脉血栓形成患者进行检查,并与数字减影血管造影(DSA)检查结果进行比较.结果 CDUS观察49条下肢深静脉血栓形成部位与DSA结果相符,诊断符合率96%,行一致性检验的Kappa值为0.73(>0.65).结论 CDUS具有无创、实时、安全可靠的特点,是诊断急性下肢深静脉血栓形成的较为理想的方法.对CDUS结果阴性患者需动态观察、定期超声复查.

关 键 词:超声检查  多普勒  彩色  下肢深静脉血栓  急性  数字减影血管造影

Clinical value of color Doppler ultrasound in diagnosis of acute deep vein thrombosis of lower limbs
WANG Juan,WANG Weiwei,XIONG Juan. Clinical value of color Doppler ultrasound in diagnosis of acute deep vein thrombosis of lower limbs[J]. Journal of Ultrasound in Clinical Medicine, 2011, 13(4): 258-260
Authors:WANG Juan  WANG Weiwei  XIONG Juan
Affiliation:Department of Special Diagnosis, the Second Affiliated Hospital of Nanjing Medical University, Nanjing 210011, China
Abstract:Objective To explore the application value of color Doppler ultrasound in diagnosis of acute deep vein thrombosis of lower limbs, and to analyze the limited facotrs. Methods Fifty - two patients with suspected acute deep vein thrombosis of lower limbs were examined by color Doppler ultrasound, then the results were compared with those of digital subtraction angiography (DSA). Results The results of acute deep vein thrombosis in 49 lower limbs by CDUS were coincident with those by DSA, the accuracy was 96%, Kappa value was 0.73 by uniformity test(〉0.65). Conclusion CDUS has the characteristics of non -invasion, real - time, safety and reliability, and it is an effective method in diagnosis of acute deep vein thrombosis of lower limbs. When CDUS results are negative, patients need dynamical observation and regular ultrasonic re -examination.
Keywords:Ultrasonography, Doppler, color  Deep vein thrombosis of lower limbs, acute  Digital subtractionangiography
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号