Estimation of breakthrough time on activated carbon fixed bed adsorbers for multicomponent organic solvent vapors |
| |
Authors: | H Hori I Tanaka T Akiyama |
| |
Abstract: | The estimation of breakthrough time for multicomponent organic solvent vapors on activated carbon fixed beds is significantly complicated and difficult. This paper describes a simple estimation method of breakthrough time for the first component (foremost breakthrough component) in two- or three-component organic solvent vapors on an activated carbon fixed bed. The breakthrough time for the first component was expressed by the harmonic mean value of the breakthrough times in each pure component. Estimated breakthrough times were compared with the experimental ones. |
| |